OMNI624 Installation and Setup Guide
Q 13, L1 – Enter the L1 digit for the desired user options from the table below.
L1
User
Users 31,
Entry
On-line
32 Duress
0
✔
1
✔
2
✔
✔
3
4
✔
5
✔
6
✔
✔
7
8
✔
9
✔
A
✔
✔
B
C
✔
D
✔
E
✔
✔
F
U L
Door Strikes have not been evaluated for UL installations.
Q 13, L2 – Enter the L2 digit for the tamper, RTC, or tone burst options from the table below.
Key
Installer
L2
Tamper
Reset
Entry
Lockout
Tamper
0
✔
1
✔
2
✔
✔
3
4
✔
5
✔
6
✔
✔
7
8
✔
9
✔
A
✔
✔
B
C
✔
D
✔
E
✔
✔
F
6–20
No Code for
Door Users
Door Strike
20–30
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
Key Tamper Lockout: If selected, 21 key presses at a
Crystal
Tone
keypad without a valid sequence (arm, disarm, etc.) will
RTC
Burst
disable all keypads in that partition for 20 minutes.
Additionally, a tamper message will be sent if programmed
in Programming Submode 2, Question 41, L1–L2.
NOTE: Keyfobs and keyswitches are not affected by Key
✔
Tamper Lockout.
✔
Installer Reset Tamper: If selected, only the installer can
✔
reset zone tamper conditions by using installer mode 6.
✔
Crystal RTC: If selected, the control uses its internal crystal
✔
as a reference for the Real Time Clock (RTC) instead of the
✔
AC Mains input.
✔
Tone Burst: If selected, the control emits a tone burst when
✔
the following conditions occur:
✔
✔
• Upon the control answering on a ring count (program-
✔
✔
✔
✔
mable or 2-call method) of a remote download connection.
✔
✔
• After the control performs a callback to the download PC
and the downloader answers in both the attended and
unattended download modes.
This feature is required when using a modem that requires a
tone to operate.
User On-line: Allows Quick Command
downloading (#9) while on the telephone with the
central station.
Users 31, 32 Duress: Allows up to 2 duress codes
to be assigned. A duress code must be programmed
in Submode 2, Question 37, L1–L2. If duress is not
selected, then users 31 and 32 may be used as
standard user codes.
No Code for Door Strike: Allows Quick
Command for door strike as #57 only.
Door Users 20–30: Allows up to 11 codes to be
assigned that, when used, will activate the door
strike trigger (trigger/relay type 1E). See
Programming Submode 1, Questions 42, 43 for
programming the trigger types and Questions 32–
41 for programming relay types. If this option is
not selected, then users 20–30 may be used as
standard user codes.