Honeywell OMNI 624 Installation And Setup Manual page 29

Fbii security system
Hide thumbs Also See for OMNI 624:
Table of Contents

Advertisement

Section 5. System Operation
DISARMING
TO DISARM: Enter any valid four-digit user code and the ARM LED will extinguish.
If an alarm condition exists or occurred while the system was armed, the respective zone LED will
blink rapidly. This condition is classified as Alarm Memory, and can be cleared by entering a valid user
code again. Note that a user with level 4 authority (limited user) can disarm the system only if it was
armed by a lever 4 user.
RESET
Reset is accomplished through the entry of any valid user code. This can be used to reset the smoke
detectors attached to the system, silence any bells or sounders, or clear the keypad display.
BYPASS BY ZONE
Bypassing is enabled to temporarily exclude zones or points that are faulty or otherwise not ready for
operation, from activating the security system.
TO BYPASS by ZONE: Press the [BYPASS] key followed by any valid 4-digit user code, followed by
the zone number (01–24) representing the respective zone to be bypassed.
EXAMPLE: To bypass zone 6 (assume user code of 1234), press [BYPASS] + [1] + [2] + [3] + [4] + [0] +
[6]
QUICK BYPASS BY ZONE
Quick Bypassing is a programmable option (Question 14, Location 4) and allows the user to bypass
zones and points without using a user code.
TO Quick BYPASS by ZONE: Press the [BYPASS] key followed by the zone number (01–24),
representing the respective zone to be bypassed.
EXAMPLE: To bypass zone 6, press [BYPASS] + [0] + [6]
In addition, note the following rules for bypass:
• FIRE zones cannot be bypassed.
• 24-hour zones can be bypassed; however, they CANNOT be unbypassed if they are violated.
• Zones can be bypassed only while the system is disarmed, at which time the bypassed zone is
displayed.
Bypass signals will be transmitted to the central station (CS) UPON ARMING if a bypass code has
been programmed in Submode 2, Question 44, Location 1.

ZONES THAT ARE BYPASSED ARE NOT PROTECTED WHEN THE SYSTEM IS ARMED.
BYPASS LIMIT 3
The system can be programmed to allow a maximum of 3 zones to be manually bypassed in a partition.
You can also program the system to display bypasses while armed. See Submode 1, Question 16,
Location 1.
5–7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents