OMNI624 Installation and Setup Guide
QUESTION 31 NOT USED
QUESTIONS 32–43 TRIGGER/RELAY TYPES
These questions set relay and trigger types. Momentary trigger times in seconds or minutes for each
partition are set in Questions 65 and 66.
Each trigger definition requires 2 locations to define its operation. L1 defines the partition in addition
to the type that the trigger is to respond to. L2 completes the type definition entry. Some triggers types
are not partition-independent functions, such as loss of AC. Triggers that are momentary can follow
either a second timer or a minute timer as described for that trigger type. Each partition has both a
minute and second programmable time. Note that all momentary triggers for a partition will follow the
momentary time (seconds or minutes) programmed for that partition. Each timer may be programmed
for 1-15.
NOTE: Triggers 3 and 4 (Question 43) may not be programmed if the 4705 Relay Module is enabled
(Submode 1, Question 12, Location 2).
Enter a relay type from the following table for each relay used.
P1
P2 Relay Type
00
00
Disabled
01
41
Burg Bell no Bell Test
02
42
Fire Bell no Bell Test
03
43
Partition Armed
04
44
Partition Ready
05
45
In Entry Delay
06
46
In Exit Delay
07
47
Armed Instant
08
48
Armed Stay
09
49
Sounder on/pulsing
0A
4A
Chime
0B
n/a
Line Seize (System)
0C
n/a
Phone Fail (System)
0D
n/a
AC Loss (System)
0E
n/a
Low Battery (System)
0F
4F
24 Hr Zone in Trouble
10
50
24 Hr Zone Alarmed
11
51
Instant Zone Faulted
12
52
Delay Zone Faulted
13
53
Interior Zone Faulted
14
54
Zone Tamper
15
55
RF Low Battery
16
56
RF Supervision
17
n/a
Comm. Fail (System)
6–38
Description
Turns on with the burg bell and turns off when the bell times out or is shut
off.
Steady output that starts when the fire bell starts. Turns off when the fire
bell times out or is turned off.
Is on when the selected partition is armed; otherwise is off.
Is on when the selected partition is disarmed; otherwise is off.
Is on if the selected partition is in entry delay; otherwise is off.
Is on if the selected partition is in exit delay; otherwise is off.
Is on if the selected partition is armed in the instant mode; otherwise is off.
Is on if the selected partition is armed in the stay mode; otherwise is off.
Follows either a pulsing sounder or steady sounder for the selected
partition.
Is activated for 1 second if a chime zone is activated for the programmed
partition.
System trigger is on when the phone line is seized.
System trigger is on if the phone line monitor has detected the phone line
has been cut.
System trigger is on when no AC loss is detected.
System trigger is on when the battery voltage falls below 10.2 volts.
On if any 24-hour trouble in the selected partition is active.
On if any 24-hour alarm zone in the selected partition is active.
On if any instant zone in the selected partition is faulted.
On if any delay zone is faulted in the selected partition.
On if any interior zone is faulted in the selected partition.
On if any Tamper has occurred on a zone. Includes RF and hardwired (if
double balanced).
On if any low battery has been detected on an RF zone for that partition.
On if any RF zone has not been received for the programmed supervision
interval.
On when comm fails occurs, off after code is entered, by partition.