Honeywell OMNI 624 Installation And Setup Manual page 31

Fbii security system
Hide thumbs Also See for OMNI 624:
Table of Contents

Advertisement

Level
Functions Allowed
1
Primary Master can view log and set time, assign other user codes, all system functions
2
Secondary Master, same as primary Master except cannot change the primary Master's code
3
User, can arm and disarm only
4
Limited user, same as level 3, except can disarm the system only if it was armed by another user with level
4 authority (cannot disarm if armed with user of higher authority level).
4/6-DIGIT USER CODES
The system supports either 4- or 6-digit user codes. A bit option in Submode 1, Question 12, Location 3
selects if the user codes are to be 4 or 6 digits in length for the entire system. The default user code for
the master is 1234 with an authority level of 1. The system is defaulted to 4-digit user/installer code. If
the bit is set in installer mode, each currently programmed code will change to six digits by adding a
"00" before the known 4-digit code.
For example, if 4-digit codes are being changed to 6 digits and a user code was 1-2-3-4, it will become 0-
0-1-2-3-4. Conversely, if the user code length was 6, and it is changed back to 4 digits, the code 1-2-3-4-
5-6 will become 3-4-5-6.
Once "6-digit user codes" is selected, new codes entered can be any combination of 6 digits.
NOTE: Selecting "6-digit user codes" also affects the installer code by adding "00" to the code (default installer code 2468
becomes 002468). Use Question 00 to enter a new installer code.
TO ADD OR CHANGE USERS:
Press [CODE] + MASTER USER CODE + USER NO. + NEW USER CODE + AUTHORITY LEVEL
where:
[CODE]
MASTER USER
USER NO.
NEW USER CODE
AUTHORITY LEVEL The desired authority level for the new user.
EXAMPLE: Define user number 03 with a code of 7493 and authority level 3. (Assume Master code is
1234) = CODE 1234 03 7493 3
An acknowledgment (steady tone) verifies a successful user code programming. A negative
acknowledgment (4 short tones) indicates unsuccessful programming. If additional user programming
is necessary, repeat the procedure listed above. If a dialing format is programmed that transmits
opening/closing by user ID, each user will report their user number.
ASSIGNING PARTITIONS AND PAGER OPEN/CLOSE REPORTS TO USERS
Users are automatically enabled for the partition where their code was added. You can also allow users
to access other partitions and/or enable open/close pager reports for a user by using the #7 command as
follows:
[#] + [7] + MASTER USER CODE + USER NO. + [1], [2], or [4]
[CODE] button on keypad.
4- or 6-digit* Master User code (user with authority level 1 or 2)
Desired user number to be programmed (01–32).
4- or 6-digit* user code for the new user. Valid digits are 0–9.
*(Depending on the whether the system is set for 4- or 6-digit security codes)