Honeywell OMNI 624 Installation And Setup Manual page 52

Fbii security system
Hide thumbs Also See for OMNI 624:
Table of Contents

Advertisement

OMNI624 Installation and Setup Guide
Q 07
SECONDARY ACCOUNT NUMBER PARTITION 1
Q 08
PRIMARY ACCOUNT NUMBER PARTITION 2
Q 09
SECONDARY ACCOUNT NUMBER PARTITION 2
QUESTION 10 CS DIALER FORMAT AND RECEIVER TYPE
This question defines the dialer format and receiver type for primary (CS1) and secondary (CS2)
reporting. Enter the digits as follows:
Q 10: L1/L3 CS1 and CS2 Dialer Format – Enter the L1 and L3 digits for the desired dialer format
from the table below.
L1/L3
CS REPORTING
ENTRY TYPE
3x1 Standard
0
1
4x1 Standard
3x1 Extended
2
4x1 Extended
3
4
3x1 Partial Extended
4x1 Partial Extended
5
6
3x2
7
4x2
FBII Superfast
8
9
ADEMCO 4x1 Express *
A
ADEMCO 4x2 Express *
ADEMCO Contact ID *
E
6–14
FORMAT
FORMAT
TRANSMISSION
PULSE
PULSE
PULSE
PULSE
PULSE
PULSE
PULSE
PULSE
DTMF
DTMF
DTMF
DTMF
L1
L1
L1
L1
L2
CS1
NOTE: For more information on CS
reporting formats, refer to Appendix A at
the back of this manual.
* These formats require a high/low
handshake frequency from the CS
receiver.
L2
L3
L4
L2
L3
L4
L2
L3
L4
L3
L4
CS2

Hide quick links:

Advertisement

Table of Contents
loading