Honeywell OMNI 624 Installation And Setup Manual page 67

Fbii security system
Hide thumbs Also See for OMNI 624:
Table of Contents

Advertisement

Q17, L3 – Enter the L3 digit for the desired events to be recorded in event log
L3 Entry
Log RF Battery
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
QUESTION 18
BELL TIMEOUT/AC DELAY/RING COUNT
Q 18, L1/L2 – Burglary Bell/Fire Bell Timeout
Enter the L1 and L2 digits for the desired burglary and fire bell/siren timeouts, respectively, from the
table below.
BURGLARY &
Entry
FIRE BELL TIMEOUTS
1
3 minutes
6 minutes
2
9 minutes
3
12 minutes
4
5
15 minutes
6
18 minutes
21 minutes
7
24 minutes
8
U L
Must be programmed as "2" for UL installations.
Log RF Supervision
Log Tamper
Entry
FIRE BELL TIMEOUTS
9
A
B
C
D
E
F
Section 6. System Programming
Log Bypass
L1
Burg bell Fire bell AC dial
timeout timeout
BURGLARY &
27 minutes
30 minutes
33 minutes
36 minutes
39 minutes
42 minutes
Infinite
L2
L3
L4
Ring
delay
count
6–29

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents