Step 2 Framing The Fireplace - Heat-N-Glo SL-36 Installer's Manual

Fireplace
Hide thumbs Also See for SL-36:
Table of Contents

Advertisement

For Horizontal Sections
Top
3 inches
(75 mm) (25 mm) (25 mm)
Step 2
Framing the
Fireplace
CAUTION
The framing headers may rest
on the fireplace stand-offs.
Model
SL-36 Models
SL-36(Clean Face)
SL-32 Models
Figure 7. Framing Dimensions
11
Minimum Clearances from the Vent Pipe to
Combustible Materials
For Vertical
Bottom
Sides
1 inch
1 inch
For minimum clearances, see the direct vent
termination clearance diagrams on pages 29 and 31 in
this section.
Fireplace framing can be built before or after the
fireplace is set in place. Framing should be positioned
to accommodate wall coverings and fireplace facing
material. The diagram below shows framing reference
dimensions.
MEASURE FIREPLACE DIMENSIONS, AND
VERIFY FRAMING METHODS AND WALL
COVERING DETAILS, BEFORE FRAMING
CONSTRUCTION BEGINS.
A
42
42
37
NOTE: DIMENSIONS SHOWN IN INCHES
Sections
Top
1 inch
2-1/2 inches 1/2 inch
(25 mm)
(63.7 mm) (13 mm) (25 mm)
Framing should be
constructed of 2 X 4
lumber or heavier.
B
C
38-1/4
16-1/4 40-3/4
38-7/8
16-1/4 75-1/8
33
16-3/4 36 5/8
At Wall Firestops
Bottom
Sides
1 inch
D
E
26 1/4
----
19 1/2