Heat-N-Glo SL-36 Installer's Manual page 7

Fireplace
Hide thumbs Also See for SL-36:
Table of Contents

Advertisement

When planning a fireplace installation, it’s necessary to determine:
• Where the unit is to be installed.
• The vent system configuration to be used.
• Gas supply piping.
• Electrical wiring.
• Framing and finishing details.
• Whether optional accessories—devices such as a fan, wall switch, or remote
control—are desired.
If the fireplace is to be installed on carpeting or tile, or on any combustible
material other than wood flooring, the fireplace should be installed on a metal or
wood panel that extends the full width and depth of the fireplace.
The CFK-SL36 Clean Face Kit is designed to convert a Model SL-36 Gas
Fireplace to a “Clean Face” Design. The kit includes a top extension piece, an
upper grille cover, and a lower grille cover. See Figure 2. The following
requirements MUST be met if this kit is installed. IF THESE REQUIREMENTS
ARE NOT MET, A POTENTIAL FIRE HAZARD WILL EXIST AND THE
FIREPLACE WARRANTY WILL BE VOIDED.
1. The first vent component attached to the fireplace starting collar MUST be
a 3-foot (904 mm) length of straight pipe.
2. The top extension piece in this kit MUST be properly installed to avoid a fire
hazard.
3. The lower fireplace grille MUST be able to be opened for access to the gas
valve and controls. This condition MUST be met after the Clean Face Kit is
installed and the fireplace finishing has been completed.
4. An optional fan (kit no. GFK-160A or any other fan) CANNOT be installed in
the SL-36 fireplace when converted to a clean face fireplace.
5. Damaged components or components field-modified without factory autho-
rization cannot be installed or used. Installation instructions are included in
the CFK-SL36 Kit.