Heat-N-Glo SL-36 Installer's Manual
Heat-N-Glo SL-36 Installer's Manual

Heat-N-Glo SL-36 Installer's Manual

Fireplace
Hide thumbs Also See for SL-36:

Advertisement

Models:
SL-36
SL-36GDV
SL-32
SL-32GDV
SL-32S
WARNING
IF THE INFORMATION IN
THESE INSTRUCTIONS IS
NOT FOLLOWED EXACTLY, A
FIRE OR EXPLOSION MAY
RESULT CAUSING PROPERTY
DAMAGE, PERSONAL INJURY,
OR DEATH.
- Do not store or use gasoline or other flam-
mable vapors and liquids in the vicinity of this
or any other appliance.
- What to do if you smell gas
• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call the
fire department.
- Installation and service must be performed by a
qualified installer, service agency, or the gas
supplier.
Printed in U.S.A.
Copyright 1998
Heat-N-Glo Fireplace Products, Inc.
6665 West Highway 13, Savage, MN 55378
Heat-N-Glo Fireplace
U.S. Patents 4,793,322; 4,875,464; 5,000,162 and Patents Pending
READ THIS MANUAL BEFORE INSTALLING
OR OPERATING THIS APPLIANCE. THIS
INSTALLERS GUIDE MUST BE LEFT WITH
APPLIANCE FOR FUTURE REFERENCE.
WARNING: IMPROPER
INSTALLATION, ADJUSTMENT,
ALTERATION, SERVICE OR
MAINTENANCE CAN CAUSE
INJURY OR PROPERTY DAMAGE.
REFER TO THIS MANUAL. FOR
ASSISTANCE OR ADDITIONAL
INFORMATION CONSULT A
QUALIFIED INSTALLER, SERVICE
AGENCY, OR THE GAS SUPPLIER.
Please contact your Heat-N-Glo Fireplace
dealer for any questions or concerns. For the
number of your nearest Heat-N-Glo dealer,
please call 612-890-8367.
Installers Guide
Underwriters Laboratories Listed.
This appliance may be installed in an
1.
aftermarket, permanently located,
manufactured (mobile) home, where
not prohibited by local codes.
2. This appliance is only for use with the
type of gas indicated on the rating
plate. This appliance is not convertible
for use with other gases, unless a
certified kit is used.
Canadian Patent 1,297,746
454-980-A 4/98

Advertisement

Table of Contents
loading

Summary of Contents for Heat-N-Glo SL-36

  • Page 1 Printed in U.S.A. Please contact your Heat-N-Glo Fireplace dealer for any questions or concerns. For the Copyright 1998 number of your nearest Heat-N-Glo dealer, Heat-N-Glo Fireplace Products, Inc. please call 612-890-8367. 6665 West Highway 13, Savage, MN 55378 454-980-A 4/98...
  • Page 2: Safety And Warning Information

    SAFETY AND WARNING INFORMATION READ and UNDERSTAND all instructions carefully before starting the installation. FAILURE TO FOLLOW these installation instructions may result in a possible fire hazard and will void the warranty. Prior to the first firing of the fireplace, READ the Using Your Fireplace section of the Owners Guide.
  • Page 3: Table Of Contents

    Table of High Altitude Installations ........ 2 Contents Section 2: Getting Started ......3 Introducing the Heat-N-Glo Gas Fireplaces ..3 Pre-installation Preparation ........ 3 Section 3: Installing the Fireplace ....10 Step 1 Locating the Fireplace ......10 Step 2 Framing the Fireplace ......11 Step 3 Installing the Vent System ....
  • Page 4: Section 1: Approvals And Codes

    Approval Listings Appliance Certification and Codes Installers Guide Approvals and Codes Installation Codes...
  • Page 5: High Altitude Installations

    High Altitude Installations...
  • Page 6: Section 2: Getting Started

    Installers Guide Getting Started Pre-installation Preparation Installers Guide Introducing Heat-N-Glo Gas Fire- places...
  • Page 13: Section 3: Installing The Fireplace

    Step 1 Locating the Fireplace Installing the Fireplace Clearance Requirements...
  • Page 14: Step 2 Framing The Fireplace

    Step 2 Framing the Fireplace CAUTION MEASURE FIREPLACE DIMENSIONS, AND VERIFY FRAMING METHODS AND WALL COVERING DETAILS, BEFORE FRAMING CONSTRUCTION BEGINS. NOTE: DIMENSIONS SHOWN IN INCHES...
  • Page 15: Step 3 Installing The Vent System

    Step 3 A. Vent System Approvals Installing the Vent System Installers Guide Vent system components Vent system termination kits D-SERIES SL D-SERIES...
  • Page 16 6-7/16" 6-5/32" 8-1/2" 8-1/2" 11-5/8" 11-1/16" 7-3/8" 5-7/8" 6-1/2" 5-1/16" 8-5/8" (220 mm) 8-5/8" 11-15/16" 47-3/4" 35-3/4" DV-12D DV-09D DV-06D 11-3/4" 11 3/4 8-3/4" 8 3/4 5-3/4" 5 3/4 NOTE: PIPES OVERLAP 1 3/8 INCHES (34.93 mm) AT EACH JOINT. NOTE: PIPES OVERLAP 1-3/8 INCHES (34.93 mm) AT EACH JOINT.
  • Page 18 STRAIGHT UP VERTICAL VENTING FOR MODEL SL-36 (CLEAN FACE VERSION): V = 3-FEET (914mm) MINIMUM IN TABLE.
  • Page 19 STRAIGHT OUT HORIZONTAL VENTING Max. Run...
  • Page 20 VENTING WITH ONE (1) 90 ELBOW V (FT.) H (FT.)
  • Page 21 VENTING WITH ONE (1) 90 ELBOW V (FT.) H (FT.) FOR MODEL SL-36 (CLEAN FACE VERSION): V = 3-FEET (914mm) MINIMUM IN TABLE. FOR MODELS SL-32, SL-36 (CIRCULATING VERSION): NOTE: IF A 90° ELBOW IS FIRST ATTACHED TO THE UNIT,...
  • Page 22 VENTING WITH TWO (2) 90° ELBOWS H + H VENTING WITH TW0 (2) 90 ELBOWS V (FT) H + H (FT)
  • Page 23 VENTING WITH TWO (2) 90° ELBOWS V (FT.) H + H (FT.) 1' MIN. (305mm) 2' MAX. (610mm) FOR MODEL SL-36 (CLEAN FACE VERSION): 2' MIN. (610mm) 4' MAX. (1.22m) 3' MIN. (914mm) 6' MAX. (1.86m) V = 3-FEET (914mm) MINIMUM IN TABLES.
  • Page 24 VENTING WITH THREE (3) 90° ELBOWS V (FT.) H (FT.) H + H (FT.) 1´ MIN. (305 mm) 2´ MAX. (610 mm) 4´ MAX. (1.22 mm) 2´ MIN. (610 mm) 4´ MAX. (1.22 m) 8´ MAX. (2.48 m) 3´ MIN. (914 mm) 6´...
  • Page 25 16' MAX. (4.8m) 16’ MAX. (4.8m) V + V + H + H = 30' (9m) MAX. FOR MODEL SL-36 (CLEAN FACE VERSION): V = 3-FEET (914mm) MINIMUM IN TABLES VENTING WITH THREE (3) 90° ELBOWS V (FT.) H (FT.) H + H (FT.)
  • Page 26: Installing Vent Components

    B. Installing Vent Components STARTING STARTING COLLAR COLLAR STOVE STOVE SEALANT SEALANT BEAD BEAD 3/8" (9.5 mm) 3/8" (9.5 mm) FIRST FIRST 3/8 INCH (9.5 mm) VENT VENT COMPONENT COMPONENT 1 INCH (25.4 mm)
  • Page 28 WALL BRACKET WALL STUD 8 FT. (2.4 m) FLUE FLUE OUTLET OUTLET 1 INCH MIN. 1 INCH MIN. (25.4 mm) (25.4 mm) NOTE Model DVK-01TRD or SLK-01TRD do not need an exterior firestop on an exterior combustible wall.
  • Page 29 TRIM HEAT TRIM HEAT HEAT SHIELD SHIELD IF TOO SHIELD IF TOO LONG, ADD TO LONG, ADD TO SHIELD IF TOO SHIELD IF TOO SHORT. SHORT. EXTERIOR EXTERIOR FIRESTOP FIRESTOP INTERIOR INTERIOR FIRESTOP FIRESTOP...
  • Page 30 JOIST CEILING NAILS (4 REQUIRED) CEILING FIRESTOP...
  • Page 31: Vent Termination

    NAILS (4 REQUIRED) RAFTER CEILING CEILING FIRESTOP C. Vent Termination...
  • Page 33 openable fixed closed J or K 1 2 3 4 =VENT TERMINAL 1 2 3 4 1 2 3 4 =AREA WHERE TERMINAL IS NOT PERMITTED 1 2 3 4 1 2 3 4 =AIR SUPPLY INLET CAUTION IF EXTERIOR WALLS ARE FINISHED WITH VINYL SIDING, IT IS NECESSARY TO INSTALL THE VINYL PROTECTOR KIT TO THE TOP OF THE EXTERIOR FIRESTOP (FOR ALL ROUND...
  • Page 34 NOTE This also pertains to vertical vent systems installed on the outside of the building.
  • Page 35 TERMINATION...
  • Page 36: Securing The Fireplace

    Step 4 Positioning, Leveling, and Securing the Fireplace Step 5 The Gas Control Systems Standing Pilot Ignition Direct Spark Ignition (DSI).
  • Page 37: Step 6 The Gas Supply Line

    DSI IGNITION STANDING PILOT IGNITOR 1/2" (13 mm) 1/2" (13 mm) 3/8" (10 mm) 3/16" (5 mm) Step 6 The Gas Supply Line...
  • Page 38: Step 7 Gas Pressure Requirements

    Step 7 Gas Pressure Requirements...
  • Page 39: Step 8 Wiring The Fireplace

    Step 8 Wiring the Fireplace CAUTION DISCONNECT REMOTE CONTROLS IF YOU ARE ABSENT FOR EXTENDED TIME PERIODS. THIS WILL PREVENT ACCIDENTAL FIREPLACE OPERATION. For Standing Pilot Ignition Wiring LABEL ALL WIRES PRIOR TO DISCONNECTION CAUTION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION.
  • Page 40 FAN WIRING DIAGRAM NOTE: IF ANY OF THE ORIGINAL WIRE NOTE: IF ANY OF THE ORIGINAL WIRE VARIABLE SPEED CONTROL AS SUPPLIED WITH THE APPLIANCE AS SUPPLIED WITH THE APPLIANCE MUST BE REPLACED, IT MUST BE MUST BE REPLACED, IT MUST BE REPLACED WITH TYPE 105 DEGREE C REPLACED WITH TYPE 105 DEGREE C RATED WIRE.
  • Page 41: Step 9 Finishing

    Step 9 Finishing...
  • Page 42: Step 10 Installing Trim, Logs And Ember Material

    CAUTION IF JOINTS BETWEEN THE FINISHED WALLS AND THE FIREPLACE SURROUND (TOP AND SIDES) ARE SEALED, A 300° F. MINIMUM SEALANT MATERIAL MUST BE USED. THESE JOINTS ARE NOT REQUIRED TO BE SEALED. ONLY NON-COMBUSTIBLE MATERIAL (USING 300° F. MINIMUM ADHESIVE, IF NEEDED) CAN BE APPLIED AS FACING TO THE FIREPLACE SURROUND.
  • Page 44 CAUTION HAND TIGHTEN THE WING NUTS, BUT BE CAREFUL NOT TO OVERTIGHTEN. CAUTION IT IS STRONGLY RECOMMENDED THAT TRIM DOORS WITH OPTIIONAL MESH SCREENS BE INSTALLED ON PROPANE MODELS.
  • Page 45: Step 11 Before Lighting The Fireplace

    Step 11 Before Lighting the Fireplace Installers Guide Step 12 Lighting the Fireplace After the After the Installation Installation...
  • Page 46 Fireplace Maintenance IMPORTANT TURN OFF THE GAS BEFORE SERVICING YOUR FIREPLACE. Maintaining Type of Servicing Fireplace Fireplace Maintenance Task To Maintenance Frequency Be Completed Your Fireplace Replacing Old Ember Material Placing Ember Material INSTALLERS GUIDE. Cleaning Burner & Controls Checking Flame Patterns Flame Height...
  • Page 48: Section 5: Replacement Parts And Accessories

    Standing Pilot Only Replacement . T . Parts and . T . Accessories t i n 5 – e l i 5 – t o l i f i r t o l i f i r t o l t o l t o l .
  • Page 49 DSI Ignition Only...
  • Page 50 Both Standing Pilot and DSI Ignition i f i r – – i r T...
  • Page 51 Both Standing Pilot and DSI Ignition (Cont.) PART PART DESCRIPTION PART NUMBER Refractory SL-36, SL-36GDV SRV459-337 Refractory Base SL-32, SL-32S, SL-32GDV SRV454-337 SRV446-712 Log #1 SL-32, SL-32S SL-32GDV 81-710 Log #2 SL-32, SL-32S SL-32GDV SRV4 Log # SL-32, SL-32S SL-32GDV, SL-3...
  • Page 52 Both Standing Pilot and DSI Ignition (Cont.) PART PART PART DESCRIPTION NUMBER Log #7 SL-36, SL-36GDV, SL-32, SRV459-702 SL-32S, SL-32GDV Log #8 SL-36, SL-36GDV SRV446-714 Log #9 SL-36, SL-36GDV, SL-32, SRV446-701 SL-32S, SL-32GDV Log #10 SL-36, SL-36GDV SRV446-703 Log #11 SL-36, SL-36GDV...
  • Page 53: Accessories

    SL-36 & SL-36GDV SL-32, SL-32S & SL-32GDV Accessories l l a c t i e t i e t i...

This manual is also suitable for:

Sl-36gdvSl-32Sl-32gdvSl-32s

Table of Contents