VENTING WITH TWO (2) 90° ELBOWS
V (FT.)
H + H
1' MIN. (305mm)
2' MAX. (610mm)
2' MIN. (610mm)
4' MAX. (1.22m)
3' MIN. (914mm)
6' MAX. (1.86m)
4' MIN. (1.22m)
8' MAX. (2.48m)
5' MIN. (1.52m)
16' MAX. (4.8m)
V+H+H
= 30’ (9m) MAX. 16' MAX. (4.8m)
1
NOTE:MAXIMUM HORIZONTAL RUN
IS 11’ (3.3M) ON UNITS EQUIPPED
WITH A VARIABLE VALVE.
Figure 16. Venting with Two 90° Elbows
(FT.)
1
FOR MODEL SL-36 (CLEAN FACE VERSION):
V = 3-FEET (914mm) MINIMUM IN TABLES.
VENTING WITH TWO (2) 90° ELBOWS
V(FT.)
H (FT.)
1' MIN. (305mm)
2' MAX. (610mm)
2' MIN. (610mm)
4' MAX. (1.22m)
3' MIN. (914mm)
6' MAX. (1.86m)
4' MIN. (1.22m)
8' MAX. (2.48m)
5' MIN. (1.52m)
16' MAX. (4.8m)
16' MAX. (4.8m)
NOTE: V + V
+ H = MAX. 30' (9m)
1