WARNING: IF THE INFORMATION
IN THESE INSTRUCTIONS IS NOT
FOLLOWED EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUS-
ING PROPERTY DAMAGE, PER-
SONAL INJURY, OR DEATH.
- Do not store or use gasoline or other flam-
mable vapors and liquids in the vicinity of this
or any other appliance.
- What to do if you smell gas
• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call
the fire department.
- Installation and service must be performed by a
qualified installer, service agency, or the gas
supplier.
This product is covered by one or more of the following patents: (United States) 4,112,913; 4,408,594; 4,422,426; 4,424,792; 4,520,791; 4,793,322;
4,852,548; 4,875,464; 5,000,162; 5,016,609; 5,076,254 5,191,877; 5,218,953; 5,328,356; 5,429,495; 5,452,708; 5,542,407; 5,613,487; (Australia)
543790; 586383; (Canada) 1,123,296; 1,297,746; 2,195,264; (Mexico) 97-0457; (New Zealand) 200265; or other U.S. and foreign patents pending.
READ THIS MANUAL BEFORE INSTALLING OR
OPERATING THIS APPLIANCE. THIS INSTALLERS
GUIDE MUST BE LEFT WITH APPLIANCE FOR
FUTURE REFERENCE.
WARNING: IMPROPER INSTALLA-
TION, ADJUSTMENT, ALTERATION,
SERVICE OR MAINTENANCE CAN
CAUSE INJURY OR PROPERTY DAM-
AGE. REFER TO THIS MANUAL. FOR
ASSISTANCE OR ADDITIONAL INFOR-
MATION CONSULT A QUALIFIED IN-
STALLER, SERVICE AGENCY, OR THE
GAS SUPPLIER.
Please contact your Heat-N-Glo dealer for any
questions or concerns. For the number of your
nearest Heat-N-Glo dealer, please call 952-985-6000.
Printed in U.S.A. Copyright 2000,
Heat-N-Glo, a division of Hearth Technologies Inc.
20802 Kensington Boulevard, Lakeville, MN 55044
1
Installers Guide
Underwriters
Laboratories Listed
541-985C 4/00

Advertisement

Table of Contents
loading

Summary of Contents for Heat-N-Glo SL-350TV

  • Page 1 GAS SUPPLIER. • Do not try to light any appliance. • Do not touch any electrical switch. Please contact your Heat-N-Glo dealer for any • Do not use any phone in your building. questions or concerns. For the number of your •...
  • Page 2: Safety And Warning Information

    SAFETY AND WARNING INFORMATION These units MUST use one of the vent systems READ and UNDERSTAND all instructions carefully described in the Installing the Fireplace section of before starting the installation. FAILURE TO the Installers Guide. NO OTHER vent systems or FOLLOW these installation instructions may result components MAY BE USED.
  • Page 3: Table Of Contents

    Appliance Certification..............6 Installation Codes ................6 High Altitude Installations ............... 6 Section 2: Getting Started ............7 Introducing the Heat-N-Glo Gas Fireplaces ........7 Pre-installation Preparation ............7 Section 3: Installing the Fireplace ..........9 Step 1 Locating the Fireplace ........... 9 Step 2 Framing the Fireplace............
  • Page 4: Section 1: Approvals And Codes

    (current edition). The Uniform Mechanical Code - (current edition), and local Building Officials for the options allowed The Heat-N-Glo fireplace models discussed in this Installers in obtaining an effective bedroom volume of unconfined Guide have been tested to certification standards and listed space.
  • Page 5: Section 2: Getting Started

    Getting Started Introducing the Heat-N-Glo Gas Fireplaces The Heat-N-Glo Warranty will be voided by, and Heat-N-Glo disclaims any responsibility for, the following actions: Heat-N-Glo B-type vent gas fireplaces are designed to op- • Installation of any damaged fireplace or vent system erate with all exhaust gases expelled to the outside of the component.
  • Page 6 2 1/4 (57mm) 28 (711mm) 3 1/2 (89mm) 5 3/8 (138mm) 33 (837mm) 8 (203mm) TOP STANDOFFS VENT COLLARS HOOD RATING PLATES & LABELS GAS CONTROLS BOTTOM GRILLE COVER GAS LINE ACCESS ELECTRICAL ACCESS Figure 1. Diagram of the SL-350TV...
  • Page 7: Section 3: Installing The Fireplace

    Minimum Clearances from the Fireplace to Combustible Materials Inches Glass Front ......36 ....914 Installing the Fireplace Floor ........0 ....... 0 Rear ........1/2 ..... 13 Sides ......... 1/2 ..... 13 Step 1. Locating the Fireplace Top ........1 1/2 ....38 Ceiling* ......
  • Page 8: Step 3 Negative Pressure Make-Up Air

    NOTE: This fireplace will operate correctly only if adequate ventilation is provided to allow proper draft to the fireplace system. Heat-N-Glo assumes no responsibility for the improper performance of the fireplace system caused by inadequate draft due to environmental conditions, down...
  • Page 9: Step 4 Installing The Vent System

    TERMINATION CAP TERMINATION CAP A. Vent System Approvals Model SL-350TV is approved to use 4-inch (102mm) diameter B-type vent. B-type vent must be used when the vent system is within combustible construction. This model may also use single wall rigid or flexible gas...
  • Page 10: Bedroom Installation In Canada

    Step 5. Positioning, Leveling, and C. Bedroom Installation in Canada Securing the Fireplace This model MUST NOT be vented into a vent system in- stalled exterior to a building. The part of the vent system To properly position, level, and secure the fireplace: above the roof line can be exterior to the building.
  • Page 11: Step 7 The Gas Supply Line

    Step 7. The Gas Supply Line Step 8. Gas Pressure Requirements NOTE: Have the gas supply line installed by a qualified Pressure requirements for Heat-N-Glo gas fireplaces service technician in accordance with all building codes. are shown in the table below.
  • Page 12: Step 9 Wiring The Fireplace

    Figure 10. Standing Pilot Ignition Wiring Diagram Step 9. Wiring the Fireplace NOTE: THIS UNIT IS NOT APPROVED FOR USE WITH NOTE: Electrical wiring must be installed by a licensed A BLOWER. electrician. CAUTION: DISCONNECT REMOTE CONTROLS IF AB- Remote Wall Switch SENT FOR EXTENDED TIME PERIODS.
  • Page 13 For Direct Spark Ignition (DSI) Remote Wall Switch Appliance Requirements Position the remote wall switch in the desired position on a This appliance requires that 110-120 VAC be wired to the wall. Run a maximum of 25 feet (7.8 m) or less of 16 A.W.G. junction box included in the manual bag assembly.
  • Page 14: Step 10 Finishing

    Step 10. Finishing Step 11. Installing Trim, Logs, and Ember Material Figure 12 shows the minimum vertical and corresponding maximum horizontal dimensions of fireplace mantels or other Installing the Trim combustible projections above the top front edge of the Combustible materials may be brought up to the specified fireplace.
  • Page 15: Placing The Ember Material

    Placing the Ember Material Double-check that grate shipping support was re- moved (see page 16). Ember material is shipped with this gas fireplace. The bag labeled Glowing Ember (050-721) is standard glowing ember • Make sure that the grate is resting directly on the refrac- material.
  • Page 16: Section 4: Maintaining And Servicing Your Fireplace

    Maintaining and Servicing Your Fireplace Fireplace Maintenance Although the frequency of your fireplace servicing and main- tenance will depend on use and the type of installation, you should have a qualified service technician perform an appli- ance check-up at the beginning of each heating season. See the table below for specific guidelines regarding each fireplace maintenance task.