Step 4
Positioning,
Leveling, and
Securing the
Fireplace
1. Place the fireplace
into position.
2. Level the fireplace
from side to side and
from front to back.
3. Shim the fireplace
with non-combus-
tible material, such
as sheet metal, as
necessary.
4. Secure the fireplace
to the framing by
nailing or screwing
Step 5
The Gas Control
Systems
33
The diagram below shows how to properly position,
level, and secure the fireplace.
Figure 30. Proper Positioning, Leveling, and
Securing of a Fireplace
WARNING
THIS UNIT IS NOT FOR USE WITH
SOLID FUEL.
Two types of gas control systems are used with
these models: Standing Pilot Ignition and Direct
Spark Ignition (DSI). Model SL-32S has Standing
Pilot Ignition only.
Standing Pilot Ignition System
This system includes millivolt control valve, standing
pilot, thermopile/thermocouple flame sensor, and
piezo ignitor.
WARNING
110-120 VAC MUST NEVER BE
CONNECTED TO A CONTROL VALVE
IN A MILLIVOLT SYSTEM.
Direct Spark Ignition (DSI) System
This system includes a 24V control valve, electronic
module, transformer, and spark ignitor/flame sensor.
WARNING
110-120 VAC MUST BE WIRED TO THE
FIREPLACE JUNCTION BOX IN A DSI
SYSTEM.
WARNING
DIRECT VENT PROPANE MODELS
WITH DSI CONTROL SYSTEMS
CANNOT BE USED IN CANADA.