Download Print this page
Heat-N-Glo SL-36 Installer's Manual
Heat-N-Glo SL-36 Installer's Manual

Heat-N-Glo SL-36 Installer's Manual

Fireplace
Hide thumbs Also See for SL-36:

Advertisement

Quick Links

This product is covered by one or more of the following patents: (United States) 4,112,913; 4,408,594; 4,422,426; 4,424,792; 4,520,791; 4,793,322;
4,852,548; 4,875,464; 5,000,162; 5,016,609; 5,076,254 5,191,877; 5,218,953; 5,328,356; 5,429,495; 5,452,708; 5,542,407; 5,613,4 87; (Australia) 543790;
5 8 6 3 8 3 ; ( C a n a d a ) 1 , 1 2 3 , 2 9 6 ; 1 , 2 9 7 , 7 4 6 ; 2 , 1 9 5 , 2 6 4 ; ( M e x i c o ) 9 7 - 0 4 5 7 ; ( N e w Z e a l a n d ) 2 0 0 2 6 5 ; o r o t h e r U . S . a n d f o r e i g n p a t e n t s p e n d i n g .

Advertisement

loading
Need help?

Need help?

Do you have a question about the SL-36 and is the answer not in the manual?

Questions and answers

Summary of Contents for Heat-N-Glo SL-36

  • Page 1 This product is covered by one or more of the following patents: (United States) 4,112,913; 4,408,594; 4,422,426; 4,424,792; 4,520,791; 4,793,322; 4,852,548; 4,875,464; 5,000,162; 5,016,609; 5,076,254 5,191,877; 5,218,953; 5,328,356; 5,429,495; 5,452,708; 5,542,407; 5,613,4 87; (Australia) 543790; 5 8 6 3 8 3 ; ( C a n a d a ) 1 , 1 2 3 , 2 9 6 ; 1 , 2 9 7 , 7 4 6 ; 2 , 1 9 5 , 2 6 4 ; ( M e x i c o ) 9 7 - 0 4 5 7 ; ( N e w Z e a l a n d ) 2 0 0 2 6 5 ; o r o t h e r U . S . a n d f o r e i g n p a t e n t s p e n d i n g .
  • Page 15 Vent system Vent system components termination kits...
  • Page 21 FOR MODEL SL-36 (CLEAN FACE VERSION): V = 3-FEET (914mm) MINIMUM IN TABLE.
  • Page 23 FOR MODEL SL-36 (CLEAN FACE VERSION): V = 3-FEET (914mm) MINIMUM IN TABLES.
  • Page 25 FOR MODEL SL-36 (CLEAN FACE VERSION): V = 3-FEET (914mm) MINIMUM IN TABLES V (FT.) H (FT.) H + H (FT.) 1' MIN. (305mm) 2' MAX. (610mm) 4' MAX. (1.22m) 2' MIN. (610mm) 4' MAX. (1.22m) 8' MAX. (2.48m) 3' MIN. (914mm) 6' MAX. (1.86m) 12' MAX.
  • Page 29 TRIM HEAT TRIM HEAT HEAT SHIELD SHIELD IF TOO SHIELD IF TOO LONG, ADD TO LONG, ADD TO SHIELD IF TOO SHIELD IF TOO SHORT. SHORT. EXTERIOR EXTERIOR FIRESTOP FIRESTOP INTERIOR INTERIOR FIRESTOP FIRESTOP...
  • Page 30 JOIST CEILING NAILS (4 REQUIRED) CEILING FIRESTOP...
  • Page 31 NAILS (4 REQUIRED) RAFTER CEILING CEILING FIRESTOP...
  • Page 33 openable fixed closed J or K 1 2 3 4 =VENT TERMINAL 1 2 3 4 1 2 3 4 =AREA WHERE TERMINAL IS NOT PERMITTED 1 2 3 4 1 2 3 4 =AIR SUPPLY INLET...
  • Page 37 DSI IGNITION IGNITOR 1/2" (13 mm) 1/2" (13 mm) 3/16" (5 mm)
  • Page 42 WARNING: TOP 1/4-INCH MINIMUM SEAL JOINT MUST BE SEALED WITH HIGH-TEMP SEALANT.
  • Page 48 PART PART PART DESCRIPTION NUMBER Valve LP - SL-32, SL-32GDV, SRV60-521 SL-32S, SL-36, SL-36GDV Valve NG - SL-32, SL-32GDV, SRV60-520 SL-32S, SL-36, SL-36GDV Piezo Ignitor SRV60–513 Thermopile SRV60–512 Thermocouple SRV446-511 Pilot Orifice LP SRV446-517 Pilot Orifice NG SRV446-505 Pilot Assembly LP...
  • Page 49 PART PART DESCRIPTION PART NUMBER Piezo Ignitor SRV60-513 Thermopile SRV60-512 Thermocouple SRV418-514 On/Off Rocker Switch SRV60–525A Valve LP SRV418-501 Valve NG SRV418-500 Burner Tube SRV429-300 Pilot Tube SRV571-301 Pilot Orifice LP SRV571-517 Pilot Orifice NG SRV571-516 Pilot Assembly LP SRV571-511A Pilot Assembly NG SRV571-510A...
  • Page 52 PART PART DESCRIPTION PART NUMBER Refractory SL-36, SL-36GDV SRV459-337 Refractory Base SL-32, SL-32S, SL-32GDV SRV454-337 SRV446-712 Log #1 SL-32, SL-32S SL-32GDV 81-710 Log #2 SL-32, SL-32S SL-32GDV SRV4 Log # SL-32, SL-32S SL-32GDV, SL-3 02-701 SRV4 SL-3 Log #4 SL-32, SL-32S...
  • Page 53 PART PART PART DESCRIPTION NUMBER Log #7 SL-36, SL-36GDV, SL-32, SRV459-702 SL-32S, SL-32GDV Log #8 SL-36, SL-36GDV SRV446-714 Log #9 SL-36, SL-36GDV, SL-32, SRV446-701 SL-32S, SL-32GDV Log #10 SL-36, SL-36GDV SRV446-703 Log #11 SL-36, SL-36GDV SRV446-704 Log #12 SL-36, SL-36GDV...

This manual is also suitable for:

Sl-36gdvSl-32gdvSl-32Sl-32s