Advertisement

Quick Links

Models:
Pier-PV-IPI
ST-PV-IPI
WARNING: IF THE INFORMATION
IN THESE INSTRUCTIONS IS NOT
FOLLOWED EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUS-
ING PROPERTY DAMAGE, PER-
SONAL INJURY, OR DEATH.
- Do not store or use gasoline or other flam-
mable vapors and liquids in the vicinity of
this or any other appliance.
-
What to do if you smell gas
• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call
the fire department.
- Installation and service must be performed by
a qualified installer, service agency, or the gas
supplier.
Printed in U.S.A. Copyright 2004
Heat-N-Glo, a brand of Hearth & Home Technologies Inc.
20802 Kensington Boulevard, Lakeville, MN 55044
This product is covered by one or more of the following patents: (United States) 4,112,913; 4,408,594; 4,422,426; 4,424,792; 4,520,791; 4,793,322; 4,852,548;
4,875,464; 5,000,162; 5,016,609; 5,076,254 5,191,877; 5,218,953; 5,328,356; 5,429,495; 5,452,708; 5,542,407; 5,613,487; (Australia) 543790; 586383; (Canada)
1,123,296; 1,297,746; 2,195,264; (Mexico) 97-0457; (New Zealand) 200265; or other U.S. and foreign patents pending.
READ THIS MANUAL BEFORE INSTALLING OR
OPERATING
THIS
INSTALLERS GUIDE MUST BE LEFT WITH
APPLIANCE FOR FUTURE REFERENCE.
WARNING: IMPROPER INSTALLA-
TION, ADJUSTMENT, ALTERATION,
SER VICE OR MAINTENANCE CAN
CAUSE INJURY OR PROPERTY DAM-
AGE. REFER TO THIS MANUAL. FOR
ASSISTANCE OR ADDITIONAL INFOR-
MATION CONSULT A QUALIFIED IN-
STALLER, SERVICE AGENCY , OR THE
GAS SUPPLIER.
1. This appliance may be installed in an af-
termarket, permanently located, manu-
factured (mobile) home, where not pro-
hibited by local codes.
2. This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with
other gases, unless a certified kit is used.
Please contact your Heat-N-Glo dealer with any
questions or concerns. For the number of your nearest
Heat-N-Glo dealer, please call 1-888-427-3973.
1
Installers Guide
Underwriters
Laboratories Listed
APPLIANCE.
THIS
2037-900C
2/04

Advertisement

Table of Contents
loading

Summary of Contents for Heat-N-Glo Pier-PV-IPI

  • Page 1 Printed in U.S.A. Copyright 2004 Please contact your Heat-N-Glo dealer with any questions or concerns. For the number of your nearest Heat-N-Glo, a brand of Hearth & Home Technologies Inc. Heat-N-Glo dealer, please call 1-888-427-3973. 20802 Kensington Boulevard, Lakeville, MN 55044 This product is covered by one or more of the following patents: (United States) 4,112,913;...
  • Page 2: Safety And Warning Information

    Safety and Warning Information These units MUST use one of the vent systems READ and UNDERSTAND all instructions carefully described in the Installing the Fireplace section of the before starting the installation. FAILURE TO Installers Guide. NO OTHER vent systems or FOLLOW these installation instructions may result in components MAY BE USED.
  • Page 3: Table Of Contents

    Appliance Certification ................9 Installation Codes ..................9 High Altitude Installations ................. 9 Getting Started ..................10 Introducing the Heat-N-Glo Gas Fireplaces ..........10 Pre-install Preparation ................10 Installing the Fireplace ..............13 Step 1. Locating the Fireplace..............13 Step 2. Framing the Fireplace ..............13 Step 3.
  • Page 4: Approvals And Codes

    Appliance Certification High Altitude Installations U.L. Listed gas appliances are tested and approved with- The Heat-N-Glo fireplace models discussed in this out requiring changes for elevations from 0 to 2,000 feet Installers Guide have been tested to certification standards in the U. S. A. and in Canada.
  • Page 5: Getting Started

    Getting Started Introducing the Heat-N-Glo Gas Fireplaces The Heat-N-Glo Warranty will be voided by, and Heat-N- Glo disclaims any responsibility for, the following actions: Heat-N-Glo gas fireplaces are designed to operate with all • Installation of any damaged fireplace or vent system exhaust gases expelled to the outside.
  • Page 6 (266mm) ACCESS 8-1/2” (216mm) 17-15/16” (455mm) 37-7/16” 2-5/16” 6-1/16” (950mm) (58mm) 24” (153mm) (610mm) 4-3/4” 4-1/2” (121mm) (114mm) 4-1/16” (102mm) TOP STANDOFFS SIDE GLASS DOOR GAS CONTROLS & LABELS ELECTRICAL GAS LINE ACCESS ACCESS Figure 1. Diagram of the PIER-PV-IPI...
  • Page 7 1/2” (13mm) 47-5/8” Ø 4 ” 12” (1208mm) (100mm) (304mm) 46-5/8” (1183mm) ELECTRICAL ACCESS 42” (1067mm) 32-5/16” (820mm) 26-5/8” 4-1/2” (676mm) (114mm) 21” GAS LINE 32-3/4” (533mm) 10-1/2” ACCESS (829mm) (266mm) 2-5/16” (58mm) 36-3/16” 24” 6-1/16” (919mm) (610mm) (153mm) 8-1/2” 4-3/4”...
  • Page 8: Installing The Fireplace

    Glass Sides or Ends ..36 ....914 Floor ........ 0 ...... 0 Rear Vent ......1/2 ....13 1/2” Metal Sides or Ends ..1/2 ....13 PIER-PV-IPI Top......... 2 1/2....64 TOP VIEW GLASS GLASS Ceiling* ......31 ....787...
  • Page 9 Shows center of 12” x 12” vent framing holes for venting. Framing should be constructed of 2 X 4 lumber or heavier. PIER-PV-IPI ST-PV-IPI Model PIER-PV-IPI 42-1/8 42-1/2 25-5/8 ST-PV-IPI 47-5/8 42-1/2 26-5/8 NOTE: DIMENSIONS SHOWN IN INCHES Figure 4.
  • Page 10: Step 3. Installing The Vent System

    Step 3. Installing the Vent System A. Vent System Approvals These models are approved to use PVFLEX series vent Detailed installation instructions are included with each vent pipe components and terminations (see Figure 5). Ap- termination kit and should be used in conjunction with this proved vent system components are labeled for identifi- Installers Guide.
  • Page 11 STRAIGHT OUT STRAIGHT UP HORIZONTAL VENTING VERTICAL VENTING H (FT.) V (FT.) 36" MIN. (914 mm) 40' MAX. (12.2 M) 40’ MAX. (12.2 M) 8 (90 ) Bends MAX. 8 (90 ) Bends MAX. Figure 7 Figure 6 VERTICAL DROP MAX.
  • Page 12 • Inadequate make-up air (which is increasingly more SIDE COLLAR prevalent in new construction). NOTE: Heat-N-Glo assumes no responsibility for the Figure 10. Fresh Air Kit improper performance of the fireplace system or other Using 4 inch Class-I flex vent make the connection to the...
  • Page 13: Installing Vent Components

    B. Installing Vent Components NOTE: There must be NO INSULATION or other 1. Attach the First Vent Component to the combustibles inside the framed firestop opening. Starting Collars For Vertical Runs - One ceiling firestop is REQUIRED at To attach the first vent component to the starting collars the hole in each ceiling through which the vent passes.
  • Page 14: Vent Termination

    If the area above the ceiling is NOT an attic, position and WARNING: VENTING TERMINALS SHALL secure the ceiling firestop on the ceiling side of the NOT BE RECESSED INTO A WALL OR previously cut and framed hole. SIDING. VENT TERMINATION CLEARANCES MUST BE FOLLOWED TO AVOID FIRE DANGER.
  • Page 15 3 feet below the termination cap. 3. All gravity air intakes within 3 feet of a termination cap must be Heat-N-Glo assumes no responsibility for the improper perfor- a minimum of 1 foot below the termination cap.
  • Page 16 For Vertical Terminations - To locate the vent and install To seal the roof hole, and to divert rain and snow from the the vent sections: vent system: • Locate and mark the vent centerpoint on the underside • Attach a flashing to the roof using nails, and use a non- of the roof, and drive a nail through the centerpoint.
  • Page 17: Step 4. Positioning, Leveling, And Securing The Fireplace

    Step 4. Positioning, Leveling, and Securing Step 5. The Gas Control System the Fireplace WARNING: THIS UNIT IS NOT FOR USE The diagram below shows how to properly position, WITH SOLID FUEL. level, and secure the fireplace. IPI PILOT FLAME SENSOR Figure 23.
  • Page 18: Step 6. The Gas Supply Line

    1/2 Step 7. Gas Pressure Requirements inch (13mm) inlet of the control valve. NOTE: If substi- Pressure requirements for Heat-N-Glo gas fireplaces tuting for these components, please consult local codes are shown in the table below.
  • Page 19: Step 8. Wiring The Fireplace

    OPTIONAL ELECTRIC EMBER KIT (EMBERKIT-MS) IGNITION MODULE 3 VAC BULB SOCKET ASSEMBLY (3) INTERMITTENT PILOT IGNITOR PLUG-IN 3V TRANSFORMER ON/OFF WALL SWITCH FLAME SPARKER/ SENSOR IGNITION MODULE (3V) GROUND TO FIREPLACE CHASSIS VALVE LOW VOLTAGE SEE NOTE 1 GROUND REMOTE CONTROL NEUTRAL SCALE 1/1...
  • Page 20 NOTE: If any of the original wire as supplied with the appliance must be replaced, it must be replaced with the type 105 C rated wire. TEMPERATURE SENSOR SWITCH JUNCTION SPEED CONTROL (RHEOSTAT) DETAIL A SCALE 1/1 SEE DETAIL A Figure 26.
  • Page 21: Step 9. Finishing

    10” 9” 8” ST-PV-IPI 7” 6” TOP EDGE 5” Mantel dimensions shown are 4” for standard hood on models: 16” 3” 15” PIER-PV-IPI. SIDE EDGE 14” 13” 2” 12” 11” 1” 10” 9” 8” 7” To use mantel dimensions 6”...
  • Page 22: Step 10. Installing Trim, Logs & Ember Material

    PIER-PV-IPI TEMPERED ST-PV-IPI TEMPERED Heat-N-Glo fireplaces manufactured with tempered glass may be installed in hazardous locations such as bathtub enclosures as defined by the CPSC. The tempered glass has been tested and certified to the requirements of ANSI Z97.1-1984 and CPSC 16 CFR 1202. (Safety Glazing Cer- tification Council SGCC # 1595 and 1597.
  • Page 23: Placing The Ember Material

    Placing the Ember Material Optional Ember Light Kit (Emberkit-MS) Ember material is shipped with this gas fireplace. The bag Ember Light Bulb Replacement labeled Glowing Ember (050-721) is standard glowing em- In the lower gas valve compartment you will find three ac- ber material.
  • Page 24: Step 11. Before Lighting The Fireplace

    A small amount of air will be in the gas supply lines. When Step 11. Before Lighting the Fireplace first lighting the fireplace, it will take a few minutes for the Before lighting the fireplace, be sure to do the following: lines to purge themselves of this air.
  • Page 25: Maintaining And Servicing Your Fireplace

    Maintaining and Servicing Your Fireplace Fireplace Maintenance Although the frequency of your fireplace servicing and main- tenance will depend on use and the type of installation, you should have a qualified service technician perform an ap- pliance check-up at the beginning of each heating season. See the table below for specific guidelines regarding each fireplace maintenance task.

This manual is also suitable for:

St-pv-ipi