7420
PCIe Cards
The Sun Fishworks Cluster Controller 200 belongs in the Cluster slot (C) only. SAS HBAs must
all be of the same type, installed in slots 1 and 8, with an optional third SAS HBA in slot 2, and
an optional fourth SAS HBA in slot 7. PCIe slots should be populated in the following order: 9
(if used), 0 (if used), 7, 2, 6, 3, 5, 4.
Connectors
The serial management connector (SER MGT) is an RJ-45 connector and provides a terminal
connection to the SP console.
The network management connector (NET MGT) is an RJ-45 connector and provides a LAN
interface to the SP console.
There are four RJ-45 Gigabit Ethernet connectors (NET0, NET1, NET2, NET3) located on the
motherboard that operate at 10/100/1000 Mbit/sec. These network interfaces must be
configured before use.
7420 Standalone and Cluster Controller
Configurations
The following tables show the configuration options for a single standalone 7420 controller or
two clustered 7420 controllers. All PCIe cards are low-profile, and must be fitted with
low-profile mounting brackets.
Standalone Base Options
This table describes 7420 standalone base configurations. Note: both 7100566 and 7100568
include a cluster card and can be configured as a single standalone or two clustered
configuration.
Mktg Part Number
TA7420-26A
TA7420-28A
7100566
7100568
50
Sun ZFS Storage 7x20 Appliance Customer Service Manual • December 2011 E26399–02
Description
S7420, no DIMMs, 2x1.86GHz-6C
S7420, no DIMMs, 2x2.00GHz-8C
S7420, no DIMMs, 4x2GHz-8C
S7420, no DIMMs, 4x2.40GHz-10C 7014573
Mfg Part Number
597-0789-01
597-0790-01
7014572