SAS2
1. Place a #1 Phillips-head screwdriver in the slot at each end of the indicator board.
2. Rotate the screw drivers out until the plastic locks clear the locking mechanism, and pull the
indicator board slightly out of the cabinet to expose the interface connector.
3. Disconnect the interface connector, and remove the indicator board from the cabinet.
4. Remove the replacement board from the packaging.
5. Align the board with the slot, and connect the interface connector.
6. Push the board into the slot, and ensure that the board is fully seated in the slot.
7. Verify that the procedure was successful by logging in to the Sun ZFS Storage appliance
software, checking the system status, and clicking the associated
Cabinets section of the Maintenance > Hardware BUI page.
SAS2
Sun Disk Shelf Overview
The Sun Disk Shelf SAS-2 is a high-availability serial attached SCSI (SAS) device in a 4U,
24-disk chassis.
Refer to
80
Sun ZFS Storage 7x20 Appliance Customer Service Manual • December 2011 E26399–02
Disk Shelf Tasks
for procedural information about replacing disk shelf components.
locator icon in the