10
10

Finishing

A. Facing Material
• Metal front faces may be covered with non-combustible
materials only.
• Facing and/or fi nishing materials must not interfere
with air fl ow through louvers, operation of louvers or
decorative fronts, or access for service.
• Facing and/or fi nishing materials must never overhang
into the glass opening.
• Observe all clearances when applying combustible
materials.
WARNING! Risk of Fire! DO NOT apply combustible
materials beyond the minimum clearances. Comply with
all minimum clearances to combustibles as specifi ed in
this manual. Overlapping materials could ignite and will
interfere with proper operation of doors and louvers.
COMBUSTIBLE MATERIAL
0 IN.
0 in.
NON-COMBUSTIBLE
A
MODEL
in.
TRUE-36
61
TRUE-42
67
TRUE-50
75
Figure 10.1 Non-combustible Facing Diagram
Heat & Glo • TRUE-36, TRUE-42, TRUE-50 Installation Manual • 2282-980 Rev. F • 8/14
0 IN.
A
B
BOARD
B
mm
in.
mm
1549
57-5/8
1464
1702
62-5/8
1591
1905
66-5/8
1692
41