A.1 FINISHING THE WALL - USING THE PROVIDED 1/2" STANDOFFS
NOTE: REFER TO DIMENSIONS SECTION FOR ALLOWABLE FINISHING DIMENSIONS REQUIRED TO FIT THE GLASS
PANELS INTO THE FIREPLACE. FINISHING MATERIALS MUST NOT OVERLAP THE DIMENSIONS HIGHLIGHTED IN GREEN
FOUND ON THE DIMENSIONS SCHEMATICS IN SECTION 3 - SPECIFICATIONS. NEVER COVER THE GLASS WITH FINISHING
MATERIALS.
NOTE: REFER TO SECTION 5 FRAMING & MANTEL REQUIREMENTS: NON-COMBUSTIBLE ZONE USING PROVIDED 1/2"
STANDOFFS FOR MORE INFORMATION.
A. No combustible materials may be within 6" [152] of the top of the fireplace.
B. 1/2" [13] CLEARANCE TO COMBUSTIBLES ON SURFACE. The fireplace ships with standoffs in
place to ensure a 1/2" [13] clearance to combustibles is maintained on the surface. See Figure 10A.1.
If the standoffs are removed, only non-combustible material can be installed against the surface of the
fireplace such as a non-combustible backer cement board. 1/2" [13] minimum thickness must be used
in the space* between the top of the 3'' trim to the combustible framing the full width of the fireplace.
The space* includes a 7" [76] above the top of the fireplace that is recommended for ease of
attachment. *= 16" [406]
C. Combustible material may cover the non-combustible material in the area mentioned in B.
D. Combustible finishing materials allowed.
E. Combustible mantel may be placed above the top of the decorative frame area. There are no re-
strictions on mantel depth.
F. Combustible hearth may be placed below the bottom of the decorative frame area.
G. (IN) Flat covers will cover the components access. Gas and electric inlets are located behind this
panel. There are three access panel options all located on the pilot side of the fireplace; interior front
(shown above), side, and inside behind the glass.
Please take consideration of which option will be used to access the components for service later
during planning.
H. Combustible framing and finishing materials allowed.
I. The 3" [76] surface behind the decorative glass frame (not shown) can not be covered with any type
of material. The glass and decorative frame will be placed on top of this surface. Fasteners must not
penetrate the 3" [76] surface.