8 8

Electrical Information

A. General Information
WARNING! Risk of Shock or Explosion! DO NOT wire
110-120 VAC to the valve or to the appliance wall switch.
Incorrect wiring will damage controls.
NOTICE: This appliance must be electrically wired
and grounded in accordance with local codes or, in the
absence of local codes, with National Electric Code
ANSI/NFPA 70-latest edition or the Canadian Electric
Code CSA C22.1.
• Wire the appliance junction box to unswitched 110-
120 VAC. This is required for proper operation of the
appliance.
• A 110-120 VAC circuit for this product must be protected
with ground-fault circuit-interrupter protection, in
compliance with the applicable electrical codes, when
it is installed in locations such as in bathrooms or near
sinks.
• Low voltage and 110-120 VAC voltage cannot be shared
within the same wall box.
ACCESS THROUGH LEFT COLUMN
(Prior to installation of non-combustible board)
Figure 8.1 Junction Box Access
36
Heat & Glo • TRUE-36, TRUE-42, TRUE-50 Installation Manual • 2282-980 Rev. F • 8/14
Junction Box Installation
The electrical junction box can be accessed three ways
during installation:
1. Through the side electrical access:
• Remove two screws to release junction box bracket
from the access plate. See Figure 3.2 and Figure
8.2.
2. Through the front left column (behind the factory-
installed non-combustible board):
• From inside remove one screw that secures junction
box to junction box bracket. See Figure 8.1 and
Figure 8.2.
3. Through the fi rebox:
• From inside remove one screw that secures junction
box to junction box bracket. See Figure 8.1 and
Figure 8.2.
Pull the electrical wires from outside the appliance
through the opening into the valve compartment and
secure wires with a Romex connector. See Figure 8.2
Make all necessary wire connections to the junction
box/receptacle and reattach the junction box/receptacle
to the outer shell.
ACCESS THROUGH FIREBOX
(After installation of non-combustible board)
GASKET
COVER