Heat & Glo TRUE-36C Installation Manual page 45

Direct vent heater
Hide thumbs Also See for TRUE-36C:
Table of Contents

Advertisement

Combustible Mantel Projections
1/2 IN.
NON-COMBUSTIBLE
MATERIAL
TRUE-36
TRUE-42
Note: All measurements in inches.
Note: Measurement is taken from top of the opening,
NOT the top of the fi replace.
Figure 10.9 Combustible Mantel Allowance - TRUE-36, TRUE-42
Combustible Mantel Projections
1/2 IN.
NON-COMBUSTIBLE
MATERIAL
TRUE-50
Note: All measurements in inches.
Note: Measurement is taken from top of the opening,
NOT the top of the fi replace.
Figure 10.10 Combustible Mantel Allowance - TRUE-50
MAX.
12
9
6
3
21
MIN.
18
1
15
12
9
FIREPLACE
OPENING
Measurement from fireplace
opening to bottom of appliance:
= 35-3/16 IN. (TRUE-36)
= 40-3/16 IN. (TRUE-42)
12
9
6
3
24
21
1
18
15
12
FIREPLACE OPENING
Measurement from fireplace
opening to bottom of appliance:
= 44-3/16 IN. (TRUE-50)
Heat & Glo • TRUE-36, TRUE-42, TRUE-50 Installation Manual • 2282-980 Rev. F • 8/14
Non-Combustible Mantel Projections
1/2 IN.
NON-COMBUSTIBLE
MATERIAL
TRUE-36
TRUE-42
Note: All measurements in inches.
Note: Measurement is taken from top of the opening,
NOT the top of the fi replace.
Figure 10.11 Non-Combustible Mantel Allowance - TRUE-36, TRUE-42
Non-Combustible Mantel Projections
1/2 IN.
NON-COMBUSTIBLE
MATERIAL
TRUE-50
Note: All measurements in inches.
Note: Measurement is taken from top of the opening,
NOT the top of the fi replace.
Figure 10.12 Non-Combustible Mantel Allowance - TRUE-50
MAX.
12
10
21
MIN.
18
6
1-1/4 IN.
FIREPLACE OPENING
Measurement from fireplace
opening to bottom of appliance:
= 35-3/16 IN. (TRUE-36)
= 40-3/16 IN. (TRUE-42)
MAX.
12
10
21
MIN.
18
6
1-1/4 IN.
FIREPLACE OPENING
Measurement from fireplace
opening to bottom of appliance:
= 44-3/16 IN. (TRUE-50)
45

Advertisement

Table of Contents