013-100149-02 Rev. 1 (01/07)
NOTES: Only the port and IP address of the projector can be changed. The subnet
mask is fixed (255.255.255.0).
CHANGING THE PORT#:
that the port number of the projector be changed from its default of 3002. If so, enter a
new port number in the Ethernet Settings menu or include the new port# in an XIP
serial command sent to the projector.
By default, communications originating from one type of serial controller—RS232 vs.
RS422 vs. Ethernet—stay on the corresponding network path. This separation is
indicated by a "Separate" setting for "Network Routing" in the Communications
menu. If you are using an RS422 controller, for example, it will communicate only
with the projector to which it is connected unless you change this setting to either
"RS232 and RS422 Joined" or "All Joined".
To relay all messages to all ports—RS232, RS422, and Ethernet—set the "Network
Routing" option in the Communications menu for each projector to "All Joined". This
configuration is useful if you are using a non-RS232 controller with the RS232 linking
available between these projectors. For example, you may want to use both an RS422-
compatible controller and an Ethernet-connected PC for working with a network of
projectors linked via their RS232 in/out ports (Figure 2.20).
To isolate just RS422 communications, select "RS232 and Ethernet Joined". In Figure
2.21 only projector #3 will respond to the RS422 controller. To isolate just Ethernet
communications, select "RS232 and RS422 Joined"—only projector #1 will respond
via Ethernet.
The GPIO (General Purpose Input Output) connector on the input panel can be used
to provide a method of interfacing a wide range of external I/O devices to the
projector.
Refer to Appendix E: System Integration for complete details on pin configuration
and how to program the various pins on the connector.
On some Ethernet networks, firewall restrictions may require
Figure 2.21. All Networks
Christie DS+60/DW30/Matrix 3000 User's Manual
Section 2: Installation and Setup
2-19