Approved Vent

Rear vent configurations use 205mm diameter Co-axial venting.
Top vent configurations use 170mm diameter co-axial venting. When using 170mm diameter vent,
attach the 205mm to 170mm reducer (Travis part # 98900165) to the fireplace.

Vent Installation

Slide the vent sections together and turn 1/4 turn until the sections lock in
place.
Screws are not required to secure the vent. However, three screws may be
used to secure vent sections together if desired.
High temperature sealant is recommended at the appliance starter section
connection (use high-temperature silicone or Mill-Pac®).
If disassembly is required, at time of re-assembly check to see if the vent
creates a tight fit. If it does not, apply high temperature sealant to the joints
of the affected sections.
Horizontal sections require a 6mm rise every 300mm of travel
Horizontal sections require non-combustible support every three feet (e.g.: plumbing tape)