22
Approved Vent
•
Rear vent configurations use 205mm diameter Co-axial venting.
•
Top vent configurations use 170mm diameter co-axial venting. When using 170mm diameter vent,
attach the 205mm to 170mm reducer (Travis part # 98900165) to the fireplace.
Vent Installation
•
Slide the vent sections together and turn 1/4 turn until the sections lock in
place.
•
Screws are not required to secure the vent. However, three screws may be
used to secure vent sections together if desired.
•
High temperature sealant is recommended at the appliance starter section
connection (use high-temperature silicone or Mill-Pac®).
•
If disassembly is required, at time of re-assembly check to see if the vent
creates a tight fit. If it does not, apply high temperature sealant to the joints
of the affected sections.
•
Horizontal sections require a 6mm rise every 300mm of travel
•
Horizontal sections require non-combustible support every three feet (e.g.: plumbing tape)
Travis Industries
Installation
(for qualified installers only)
170mm Diameter Vent
6-5/8" Diameter Vent
Reducer - # 98900165
4070620
100-01199_000