Note 2:
Due to hardware, there is a limit in the number of channels that you can configure.
You can configure the following numbers of channels:
-
DECT EUROPE, LATAM, CHINA: 1, 2, 4, 5, 8, 10 channels
-
DECT US: 1, 2, 4, 5 channels
-
PWT: 1, 2, 4, 5, 8 channels
4.8.1.9
Initialization
Once the IBS finishes the downloading, the system starts the initialization.
The system synchronizes the signals of the IBSs so that handovers are possible. The system
selects the T0, T2, or CPU main board clock as the source.
Then the system sends the following data:
-
Fixed part capabilities (Full slot, frequency control, page repetition, setup on dummy, basic
A field setup): value sent = 0x007910
-
Line length: Short line
-
Frequency plan (2 bytes)
Some countries have shifted DECT frequencies. In order to be compatible with all frequency
Figure 4.61: DECT/PWT Frequencies