Both cables should have the same length. The first interface of the system's UAI16 board
should not be used since the operator station uses those points.
4.8.1.2
NUMBER OF USEFUL BASE STATIONS
Any radio signal is subject to various propagation phenomena: attenuation, reflection and
diffraction. These phenomena are related to the environment of the Alcatel-Lucent 4070
IO/EO, and affect the radio performance of the system.
The effects can improve or deteriorate wave propagation.
Take as an example a building with a metallic structure. A radio wave will tend to be subject to
many reflections which will consequently degrade system performance.
Moreover, the range of an Alcatel-Lucent 4070 IO/EO is very dependent on the amount of
attenuation subjected to the radio wave across various zones.
The following table gives the values of global coverage zone (cell) for an Alcatel-Lucent 4070
IO/EO under normal environmental and topological conditions:
Coverage area
Area:
4.8.1.3
NUMBER OF USERS PER BASE STATION
Type of Base Station connection.
4.8.1.4
LOCATING DECT BASE STATIONS
~ 7,000 m
3 channels
6 channels
Interior
Exterior
~ 50 m
~ 400 m
2
~ 50 000 m
Number of DECT users
4
12
2