S
ERVICE
6.4
Daikin electronics (CA
2
1
62
6.3.2 Removing the electronics module out
1. Switch the unit OFF using the control panel.
w
Warning:
Disconnect the power supply (remove plug from
power point or move isolation switch to OFF).
2. Remove the inspection panel (see section 6.2).
3. Disconnect all unit-connected connectors and grounded
1
connections from the printed circuit board.
4. Remove the screws 1.
5. Remove the electronics module.
6. Disconnect the connectors from the connector plate.
n
Note:
The electronics module in your unit may look different
from the module illustrated opposite.
V and CA
2
6.4.1 Introduction
In addition to the Biddle electronics, the unit also contains a
Daikin electronics module.
6.4.2 Access to the electronics in the unit
w
Warning:
Before opening the unit:
Observe the safety instructions in section1.4.
All models
1. Remove the inspection panel 1 of the unit (see manual of
the Air Curtain Model CA).
3
2. The Biddle electronics is located at 2.
Q)
2
C
A
C
OMFORT