Parameter list
Parameter
340
Refer to Pr.79.
Remote output
495
selection
Remote output data
496
1
Remote output data
497
2
503
Maintenance timer
Maintenance timer
504
alarm output set
time
Output stop
522
frequency
539,
Refer to Pr.331 to Pr.339, Pr.341 to Pr.343.
549, 550
551
Refer to Pr.117 to Pr.124, Pr.331 to Pr.339, Pr.341 to Pr.343.
553, 554
Refer to Pr.127 to Pr.134.
Current average
555
time
Data output mask
556
time
Current average
value monitor signal
557
output reference
current
563, 564
Refer to Pr.52.
571
Refer to Pr.13.
575 to 577
Refer to Pr.127 to Pr.134.
611
Refer to Pr.57 and Pr.58.
Speed smoothing
653
control
Speed smoothing
654
cutoff frequency
Pulse increment
799
setting for output
power
867
Refer to Pr.54 to Pr.56.
872
Refer to Pr.251.
98
Incre
Initial
Name
ments
Value
1
0
1
0
1
0
1
0
1
9999
0.01Hz
9999
0.1s
1s
0.1s
0s
Rated
0.01/
inverter
0.1A
current
*15
0.1%
0
0.01Hz
20Hz
0.1kWh
1kWh
Range
Description
Remote output data
0
clear at powering off Remote output data
Remote output data
1
held at powering off
Remote output data
10
clear at powering off Remote output data
Remote output data
11
held at powering off
0 to 4095
Output terminal can be switched on and off.
0 to 4095
Displays the cumulative energization time
of the inverter in 100h increments.
0 (1 to 9998)
Reading only
Writing the setting of "0" clears the
cumulative energization time.
Set the time taken until when the
0 to 9998
maintenance timer alarm output signal
(Y95) is output.
9999
No function
Set the frequency to start coasting to a
0 to 400Hz
stop (output shutoff).
9999
No function
Set the time taken to average the current
0.1 to 1.0s
during start bit output (1s).
Set the time for not obtaining (mask)
0.0 to 20.0s
transient state data.
Set the reference (100%) for outputting the
0 to 500/
signal of the current average value.
*15 Setting increments and setting range
0 to 3600A
differ according to the inverter capacity.
*15
(55K or less/75K or more)
The torque fluctuation is reduced to
0 to 200%
reduce vibration due to mechanical
resonance.
Set the minimum value for the torque
0 to 120Hz
variation cycle (frequency).
0.1kWh,
Pulse train output of output power (Y79)
1kWh,
is output in pulses at every output
10kWh,
100kWh,
current (kWh) that is specified.
1000kWh
Para
Para
meter
meter
copy
clear
: enabled
× : disabled
clear at inverter reset
held at inverter reset
×
×
×
All
para
meter
clear
×
×
×
×
×
×
×