Parameter list
Parameter
Remote function
59
selection
Energy saving
60
control selection
65
Retry selection
Number of retries at
67
fault occurrence
Retry waiting time
68
Retry count display
69
erase
66
Refer to Pr.22 and Pr.23.
67 to 69
Refer to Pr.65.
70
Refer to Pr.30.
71
Applied motor
PWM frequency
72
selection
Soft-PWM
240
operation selection
PWM frequency
automatic
260
switchover
84
Incre
Initial
Name
ments
Value
1
0
1
0
1
0
1
0
0.1s
1s
1
0
1
0
1
2
1
1
1
1
Range
Description
RH, RM, RL signal
function
0
Multi-speed setting
1
2
Remote setting
3
11
Remote setting
12
(These setting
values enable
deceleration to the
13
frequency lower than
the set frequency.)
0
Normal operation mode
4
Energy saving operation mode
9
Optimum excitation control mode
0 to 5
A fault for retry can be selected.
0
No retry function
Set the number of retries at fault
1 to 10
occurrence. A fault output is not provided
during retry operation.
Set the number of retries at fault
occurrence. (The setting value - 100 is the
101 to 110
number of retries.) A fault output is
provided during retry operation.
Set the waiting time from when an inverter
0 to 10s
fault occurs until a retry is made.
Clear the number of restarts succeeded by
0
retry.
0
Thermal characteristics of a standard motor
Thermal characteristics of the Mitsubishi
1
constant-torque motor
Thermal characteristic of standard motor
2
Adjustable 5 points V/F
Mitsubishi standard motor (SF-JR 4P
20
1.5kW or less)
PWM carrier frequency can be changed.
The setting displayed is in [kHz].
0 to 15/
Note that 0 indicates 0.7kHz, 15
indicates 14.5kHz and 25 indicates
0 to 6, 25
2.5kHz.
*12
*12 The setting depends on the inverter
capacity (55K or less/75k or more)
0
Soft-PWM invalid
When Pr. 72="0 to 5" ("0 to 4" for the 75K or
1
more), Soft-PWM is valid.
PWM carrier frequency is constant
independently of load.
When the carrier frequency is set to 3kHz
0
or more (Pr. 72 ≥ 3), perform continuous
operation at less than 85% of the rated
inverter current.
Decreases PWM carrier frequency
1
automatically when load increases.
Para
Para
meter
meter
copy
clear
: enabled
× : disabled
Frequency setting
storage function
Used
Not used
No (Turning STF/
STR off clears
remotely-set
frequency.)
Used
Not used
Not used (Turning
STF/STR OFF clears
remotely-set
frequency.)
All
para
meter
clear