Configure Snmp - 3Com 7700 Configuration Manual

Hide thumbs Also See for 7700:
Table of Contents

Advertisement

22
C
11: S
M
HAPTER
YSTEM

Configure SNMP

ANAGEMENT
The current SNMP Agent of Ethernet switch supports SNMP V1, V2C and V3. The
MIBs supported are listed in the following table.
Table 38 MIBs Supported by the Ethernet Switch
MIB
attribute
MIB content
Public MIB
MIB II based on TCP/IP network
device
BRIDGE MIB
RIP MIB
RMON MIB
Ethernet MIB
OSPF MIB
IF MIB
Private MIB
DHCP MIB
QACL MIB
ADBM MIB
RSTP MIB
VLAN MIB
Device management
Interface management
The main configuration of SNMP includes:
Set community name
Set the Method of Identifying and Contacting the Administrator
Enable/Disable snmp Agent to Send Trap
Set the Destination Address of Trap
Set sysLocation
Set the Engine ID of a Local or Remote Device
Set/Delete an SNMP Group
Set the Source Address of Trap
Add/Delete a User to/from an SNMP Group
Create/Update View Information or Deleting a View
Set the Size of SNMP Packet Sent/Received by an Agent
Set community name
Both SNMP V1 and SNMPV2C adopt the community name authentication scheme.
The SNMP message incompliant with the community name accepted by the device
will be discarded. SNMP Community is named with a character string, which is
called Community Name. The various communities can have read-only or
read-write access mode. The community with read-only authority can only query
the device information, whereas the community with read-write authority can also
configure the device.
References
RFC1213
RFC1493
RFC2675
RFC1724
RFC2819
RFC2665
RFC1253
RFC1573

Advertisement

Table of Contents
loading

Table of Contents