Display and Debug
Device Management
System Maintenance
and Debugging
Perform the following configuration in user view.
Table 24 Set Slot Temperature Limit
Operation
Set slot temperature limit
Set backboard view
The backboard view command determines the backplane bandwidth allocated to
each slot in the Switch 7700. Currently, the Switch Fabric has the capability of
32Gbpos full duplex yet the chassis has a maximum capability of 48 Gbps full
duplex. This command sets the bandwidth available to each slot in the system.
Perform the following configuration in system view.
Table 25 Set Back Board View
Operation
Set back board view
[SW7700]set backboard view INTEGER<0-5>
MOD1
MOD2
0:
8G,
8G,
1:
8G,
8G,
2:
8G,
8G,
3:
8G,
8G,
4:
8G,
8G,
5:
8G,
8G,
The default setting is 1 (8G to slots 1 and 2, 4G to slots 3-6)
After the above configuration, execute display command in all views to display
the device management configuration, and verify the effect of the configuration.
Table 26 Display and Debug Device Management
Operation
Display the set back board view.
Display the module types and
running states of each card.
Display the running state of the
built-in fans.
Display the information about the
environment.
Display the state of the power.
The basic system configuration includes:
Set the switch hostname
Set the system clock

System Maintenance and Debugging

Command
temperature-limit slot down-value up-value
Command
set backboard view value
MOD3
MOD4
8G,
8G
4G,
4G,
8G,
4G,
8G,
6G,
6G,
6G,
6G, 4G,
4G,
Command
display backboard view
display device
display fans
display environment
display power [ powe-ID ]
13
MOD5
MOD6
4G,
4G
4G
2G
2G,
2G
2G