About Data Field Programming

The following pages list this control's data fields in numerical order. Valid entries for each field are shown in
italics. Explanations and special notes are presented below the entries.
Use the separate Programming Guide to record the data for this installation.
Data field programming involves making the appropriate entries for each of the data fields. Start Data Field
programming by entering the installer code + 8 + 0 + 0.
System Options ( 6 6 6 6 20 – 6 6 6 6 30)
20
6 6 6 6
Master Security Code
Enter 4 digits, 0-9
The Installer Code can perform all system functions
except it cannot disarm the system unless it was used to
arm the system. Use of a "9" in the last position inhibits
the "Ambush" feature.
21
6 6 6 6
Quick Arm Enable
0 = no; 1 = yes
If enabled, a user code is not needed to arm the system.
Instead, users can press the [#] followed by an arming key
to arm the system. However, the user code is always
needed to disarm the system.
22
6 6 6 6
Keyswitch Enable
0 = no; 1 = yes
23
6 6 6 6
Force Bypass Function
0 = no; 1 = yes
Allows all faulted zones to be bypassed by entering
[Security Code] + [Bypass]. Zones that are bypassed by
this function will be displayed after the bypass is
initiated.
24
6 6 6 6
NOT USED
(must be set to "00")
27
6 6 6 6
Audible Exit Warning
0 = no; 1 = yes
If selected, beeping occurs during the exit time and
changes from slow to rapid beeping during the final 5
seconds of the delay.
28
6 6 6 6
Confirmation of Arming Ding
0 = no; 1 = yes
If selected, external sounder will sound for approximately
1 second at the end of the exit time or at time of kissoff of
closing report (if programmed).
29
6 6 6 6
Fire Alarm Sounder Timeout
0 = sounder timeout; 1 = no sounder timeout
Enter "0" if sounder timeout for fire zones is desired (uses
time programmed in Field *30). Temporal pulse sounding
for a fire alarm consists of the following: 3 pulses – pause
3 pulses – pause – 3 pulses.
Data Field Programming
30
6 6 6 6
Alarm Sounder Timeout
0 = no sounder timeout; 1 = 4 min; 2 = 8 min; 3 = 12 min
If selected, beeping occurs during the exit time and
changes from slow to rapid beeping during the final 5
seconds of the delay.
Programming Hardwire Zones
Zone Types for programming Fields *31-37
0 = DISABLED (or Undefined)
1 = ENTRY/EXIT (Burglary)
2 = NOT USED
3 = PERIMETER (Burglary)
4 = INTERIOR/FOLLOWER
5 = TROUBLE BY DAY/ALARM
BY NIGHT (Burglary)
31
6 6 6 6
Zone 1 Response Type
32
6 6 6 6
Zone 2 Response Type
33
6 6 6 6
Zone 3 Response Type
34
6 6 6 6
Zone 4 Response Type
35
6 6 6 6
Zone 5 Response Type
36
6 6 6 6
Zone 6 Response Type
37
6 6 6 6
Zone 7 Response Type
Console Panic: Key B or * & #. Only Zone Types 0, 6, 7,
8, 9 apply.
38
6 6 6 6
Entry Delay
0 = 0 sec; 1 = 20 sec; 2 = 30 sec; 3 = 45 sec; 4 = 60
sec; 5 = 90 sec
Exit delay = Entry delay -15 sec
39
6 6 6 6
Zone 3 Response to Open
0 = 400 ms nominal; 1 = 10 ms nominal
Programming Hardwire Zones ( 6 6 6 6 40- 6 6 6 6 49)
For fields *40-*42 enter digits 0-9, or # + 11 for [*], 3 + 12
for [#], # + 13 for 2 second pause. If fewer than the
maximum number of digits is entered, exit the field by
pressing [*] followed by the next field number to be
programmed.
40
6 6 6 6
PABX Access Code
Enter 4 digits
To clear entries press *40*.
- 7 -
SECTION 4
6 = 24 HR (Silent)
7 = 24 HR (Audible)
8 = 24 HR (Auxiliary)
9 = FIRE (Fields *35 & *37
Only)
10 = INTERIOR W/DELAY (To
Program, enter #+10)