Defaults (where applicable) are Indicated in Text.
The following pages list all data fields in this Control (in numerical order). Use the blank programming form
to record the data for this installation. Note that both keypad LEDs flash while in Programming mode.
Note: Entering a number other than the one specified will give unpredictable results.

Installer Code

20
Enter 4 digits, 0-9

Quick Arm Enable

21
0 = do not allow quick arm
1 = allow quick arm

Keypad Backlight Timeout

22
0 = no timeout; always backlight keys
1 = turn backlighting off after inactivity

Forced Bypass

23
0 = no forced bypass
1 = provide automatic bypass of all open (faulted)
zones

RF House ID Code

24
00 = disable all wireless keypad usage
01-31 = House ID
Powerline Carrier Device (X-10) House ID
25
0 = A
4 = E
1 = B
5 = F
2 = C
6 = G
3 = D
7 = H
Chime by Zone
26
0 = no (chimes on fault of any entry/exit or perimeter
zone when Chime mode is activated
1 = yes (chimes on fault of those zones assigned to
Zone List 3 when Chime mode on)
Real Time Clock Display
27
0 = do not display the time
1 = display the time
Daylight Savings Time Start/End Month
29
0, 0 = no daylight saving time used
1-12 = start month and end month
Daylight Savings Time Start/End Week
30
0 = disable
1 = first weekend of month 5 = last weekend
2 = second weekend
3 = third weekend

Single Alarm Sounding Per Zone

31
(per armed period)
0 = no limit on alarm sounding per zone
1 = limit alarm sounding to once per arming period for
a given zone
LYNXR/LYNXR24 - Applies to Long Range Radio Output if "0"
is selected in field ✻91
LYNXR-EN - Applies to Long Range Radio Output if Long Range
Radio is connected to the Trigger Single (Neg.) terminal #8.

Fire Sounder Timeout

32
0 = yes, fire sounder timeout after time programmed in
field
33
1 = no fire sounder timeout; continue sounding until
manually turned off

Alarm Bell Timeout

33
0 = No timeout
1 = 4 min

Exit Delay

34
00-99 = exit delay time in seconds
WWW.DIYALARMFORUM.COM

Data Field Descriptions

8 = I
# + 12 = M
9 = J
# + 13 = N
# + 10 = K
# + 14 = O
# + 11 = L
# + 15 = P
4 = fourth weekend
6 = next to last
7 = 3
rd
from last
2 = 8 min
4 = 16 min
3 = 12 min
WWW.DIYALARMFORUM.COM
The Installer Code is used to enter the 4-digit Master Security Code. See
"Master Code" in the System Operation section for procedure.
If enabled, security code is not required to arm the system. The user
simply presses and holds down the AWAY or STAY key to arm.
This option allows the choice of either always backlighting the keypad or
turning the backlighting off after 10 seconds of keypad inactivity.
All zones bypassed by this function will be displayed after the bypass is
initiated.
Note: UL installations: must be 0 (no forced bypass)
The House ID identifies receivers and wireless keypads.
If a 5804BD/5804BDV Transmitter is to be used, a House ID Code MUST
be entered, and the keypad should be set to the same ID.
Powerline Carrier Devices require a House ID. This field identifies this
House ID to the Control. The Powerline Carrier Devices are
programmed in field ✻80.
This option allows the installer to define the specific zones intended to
chime when faulted while the system is in Chime mode. If enabled, these
zones are defined in zone list 3 (see ✻81 Zone List Menu Mode).
Refer to the User's Manual for setting the clock time and date.
Enter # + 10 for 10, # + 11 for 11, and # + 12 for 12.
Enter the appropriate start and end weekend of the month.
UL installations: must be 0 (no limit)
This field applies only to burglary zones (zone response types 1-5, 10),
and affects long range radio reporting but does not affect central station
reporting.
Note: This field applies only to the bell and does not affect keypad
sounds.
This Control complies with NFPA requirements for temporal pulse
sounding of fire notification appliances.
Temporal pulse sounding for a fire alarm consists of the following:
3 pulses – pause – 3 pulses – pause – 3 pulses. . .
This field determines whether the external sounder will shut off after
time allowed, or continue until manually turned off.
UL installations: must be set for a minimum of 4 min (option 1)
The system will wait the time entered before sounding an alarm if the
exit door is left open after the system has been armed.
UL installations: must be set for a maximum of 60 seconds
–17–