Data Field Descriptions - Honeywell ADEMCO LYNXR-ISIA Installation And Setup Manual

Table of Contents

Advertisement

LYNXR-ISIA Installation and Setup Guide

Data Field Descriptions

Defaults (where applicable) are Indicated in bold text.
The following pages list all data fields in this Control (in numerical order). Use the blank programming form
to record the data for this installation. Note that both keypad LEDs flash while in Programming mode.
Note: Entering a number other than the one specified will give unpredictable results.
LYNXR-ISIA validates the data entry for the Fields listed below. If data entered is not within valid range,
the control will emit a long beep indicating that entry is rejected. The control will then substitute the default
value for the invalid entry and the default value will be displayed on the keypad. The control will then
advance to the next field.
Field
Name
*34
Exit Delay
*35
Entry Delay 01
*36
Entry Delay 02
*50
Burglary Dial Delay
*57
False Alarm Options
*59
Exit Error Report Code
*64
Test Report Code
*68
Cancel Report Code
*69
Recent Closing Report Code
*76
Test Restore Report
*92
Swinger Shutdown
Installer Code
20
Enter 4 digits, 0-9
Quick Arm Enable
21
0 = do not allow quick arm
1 = allow quick arm
Keypad Backlight Timeout
22
0 = no timeout; always backlight keys
1 = turn backlighting off after inactivity
Forced Bypass
23
0 = no forced bypass
1 = provide automatic bypass of all open (faulted) zones
RF House ID Code
24
00 = disable all wireless keypad usage
01-31 = House ID
Powerline Carrier Device (X10) House ID
25
0 = A
4 = E
1 = B
5 = F
2 = C
6 = G
3 = D
7 = H
Chime by Zone
26
0 = no (chimes on fault of any entry/exit or perimeter
zone when Chime mode is activated
1 = yes (chimes on fault of those zones assigned to
Zone List 3 when Chime mode on)
Real Time Clock Display
27
0 = do not display the time
1 = display the time
Daylight Savings Time Start/End Month
29
0, 0 = no daylight saving time used
1-12 = start month and end month
Default Value
60
30
30
2
7
1
10
10
1
10
1
8 = I
# + 12 = M
9 = J
# + 13 = N
# + 10 = K
# + 14 = O
# + 11 = L
# + 15 = P
Valid Range
45-97
30-99
30-99
1-3
0-7
1-F
10-FF
10-FF
1-F
10-FF
1-2
The Installer Code is used to enter the 4-digit Master Security
Code. See "Master Code" in the System Operation section for
procedure.
Note: LYNX does not allow duplication of Installer code. If a duplicate
code is entered the entry is rejected and LYNX issues single long beep
indicating rejection. The old installer code remains unchanged.
If enabled, security code is not required to arm the system. The
user simply presses and holds down the AWAY or STAY key to
arm.
This option allows the choice of either always backlighting the
keypad or turning the backlighting off after 10 seconds of
keypad inactivity.
All zones bypassed by this function will be displayed after the
bypass is initiated.
UL installations: must be 0 (no forced bypass)
The House ID identifies receivers and wireless keypads.
If a 5804BD/5804BDV Transmitter is to be used, a House ID
Code MUST be entered, and the keypad should be set to the
same ID.
Powerline Carrier Devices require a House ID. This field
identifies this House ID to the Control. The Powerline Carrier
Devices are programmed in field ✻80.
This option allows the installer to define the specific zones
intended to chime when faulted while the system is in Chime
mode. If enabled, these zones are defined in zone list 3 (see ✻81
Zone List Menu Mode).
Refer to the User's Manual for setting the clock time and date.
Enter # + 10 for 10, # + 11 for 11, and # + 12 for 12.
- 20 -