Power Wiring Guide

AutoDome Power Wiring Connections
Refer to the following diagram to ensure proper wiring of the
AutoDome. If using the ENV-PSU for power, use the
THREE WIRE POWER distances identified below.
WARNING: Failure to correctly wire the power to the
EnviroDome could result in heater malfunction.
NOTE: If using the ENV-PSU with the AutoTracker option, the
RS-232 connections (RXD, TXD, GND) must be used.
The maximum distance for RS-232 communications is 50 ft.
TWO WIRE POWER
Transformer Output
24 VAC @
50 VA
F
EnviroDome
OR
AWG Max. Distance - ft (m)
18
90 ft (27.43)
16
140 ft (42.67)
14
225 ft (68.58)
F
I
U
O
OR
NDOOR
NITS
NLY
(UNITS NOT REQUIRING HEATERS):
24 VAC @ 20 VA
Add Wire
AWG Max. Distance - ft (m)
Jumper
18
225 ft (68.58)
16
358 ft (109.12)
14
570 ft (173.74)
C–
C+ GND RXD TXD GND H*
Dome Connector
*Heater connection for EnviroDome only.
© 2005 Bosch Security Systems
THREE WIRE POWER (EnviroDome)
Transformer
Output
24 VAC @
30 VA
F
EnviroDome
OR
AWG Max. Distance - ft (m)
18
112 ft (34.14)
16
180 ft (57.91)
14
285 ft (86.87)
24 VAC
C–
C+ GND RXD TXD GND
Dome Connector
FOUR WIRE POWER (EnviroDome)
Transformer
Transformer
Output
Output
24 VAC @
24 VAC @
20 VA
30 VA
F
EnviroDome
OR
AWG Max. Distance - ft (m)
18
16
14
H*
24 VAC
C–
C+ GND RXD TXD GND H*
Appendix A
Transformer
Output
24 VAC @
20 VA
150 ft (45.72)
239 ft (72.85)
380 ft (115.82)
24 VAC
Dome Connector