COMMUNICATION SETUP
(See FIGURE 13E for COMMUNICATION SETUP hierarchy).
Baud Rate – Controls baud rate for AutoDome communication in the Normal mode. Factory Default is 9600.
Choices: . . . . . . . . . . . . .9600*, 19200, 38400, 57600.
Bilinx - Enables/Disables the Bilinx communications directly through the coax. Factory Default is ON.
Choices: ..............On*, Off.
Restore Defaults – Restores ALL choices for this submenu ONLY, back to the Factory Defaults.
Choices: . . . . . . . . . . . . . .Yes, No.
ALARM SETUP
(See FIGURE 13F for ALARM SETUP hierarchy).
Input 1 thru 4 – Contains a submenu of choices for Input type, and the action to occur when the alarm is activated.
Alarm 1 through 4
Input – Controls the input type that the camera will be expecting. Factory Default is OFF.
Choices: . . . . . . . .OFF*, Normally Open (N.O.), Normally Closed (N.C.).
Action – There are three standard choices to determine how the AutoDome will respond when an alarm input is
activated, and one additional choice that will appear ONLY when the AutoTracker is being used.
Go to Shot – The AutoDome moves to the pre-position (shot) selected. Default is the input number.
Choices: . . . . .0 to 99.
NOTE: If 0 is selected and OSD is set to YES, the camera will not move, but will display a flashing ALARM
prompt.
OSD – Controls whether a visual ALARM prompt will be displayed. Default is YES.
Choices: . . . . .Yes*, No.
Transmit – Controls whether an alarm message will be transmitted via RS-232/RS-485. Default is NO.
Choices: . . . . .Yes, No*.
Track – Controls whether AutoTrack should be activated when an alarm occurs. Displayed on AutoTrack models
ONLY.
Choices: . . . .Yes, No.
AutoTrack / Relay Output – Contains a submenu of choices that control how the relay output will function.
Period – Controls the time period that the relay output will remain activated. Default is FOLLOW INPUT.
Choices:
FOLLOW INPUT* – The relay output will remain activated as long as the alarm input is active.
LATCHED – The relay output will latch ON and remain activated until an OFF-65 command is sent twice. The
SLIDING SCALE – from 1 sec to 10 min. The relay output remains activated for the selected time period.
Trigger By: Select which alarm input will cause the relay output to Activate. Trigger By applies to Relay Output only,
not AutoTrack.
Choices: ..........Input 1 through 4: Yes, No.
Alarm Status – Displays the states of the Alarm inputs and the relay output. This is an active display, that changes
as the Alarm Status changes. It is informational only.
Restore Defaults – Restores ALL choices for this submenu ONLY, back to the Factory Defaults.
Choices: . . . . . . . . . . . . . .Yes, No.
LANGUAGE SETUP
(See FIGURE 13G for LANGUAGE SETUP hierarchy.)
Language – Selects the language to be displayed.
Choices: English, Spanish, French, German, Polish and Portuguese.
© 2005 Bosch Security Systems
first OFF-65 command clears the alarm OSD from the display; the second OFF-65 command
deactivates the output.
Section 13
Page 30 of 40