Wiring The Power Supply Box; Wiring The Fiber Optic Model - Bosch AutoDome VG5-162-EC0 Installation Manual

Fixed camera
Table of Contents

Advertisement

AutoDome 100 Series Fixed Camera
3.4.2

Wiring the Power Supply Box

1.
NOTICE!
The Power Supply Box with transformer comes with a barrier that separates the high voltage
side on the left from the low voltage 24 VAC side on the right.
2.
3.
4.
5.
NOTICE!
All video, control, and alarm wires either pass through the Power Supply Box or by-pass it and
connect directly to the Pipe Interface Board.
3.4.3

Wiring the Fiber Optic Model

1.
2.
NOTICE!
You will need a barrel connector (not supplied) to connect the BNC connector from the Pipe
Interface Board coax cable to the Fiber Optic Module BNC connector.
3.
Bosch Security Systems, Inc.
Route the high voltage 115/230 VAC lines through the conduit fitting on the left side of
the box.
Cut and trim the high voltage 115/230 VAC power and ground wires with sufficient slack
to reach their connector terminal in the box, but not so long as to be pinched by or to
obstruct closing the Cover Door. Refer to Section 3.1.1 Parts List, page 33, for connector
location.
Attach the supplied 3-pin Power Plug to the incoming high voltage power wires in the
box. Refer to connector P101 in Table 3.1, Page 42.
If you are using UTP for video, route the UTP cable out to where the AutoDome will be
mounted. Refer to Section 5 Cable and Wire Standards, page 61 for fiber optic
specifications.
Route the low power 24 VAC wires from the right side of the Power Supply Box out to
where the AutoDome will be mounted. Attach the supplied 5-pin 24 VAC Dome plug to
the wire ends inside the box. Refer to connector P107 in Table 3.1, Page 42.
If installing a Fiber Optic model, bring the fiber optic cable into the right side of the
power supply box.
If installing a Fiber Optic model attach the incoming ST fiber plug, installed previously, to
its mating connector on the Fiber Optic Module in the power supply box. Refer to
Section 5 Cable and Wire Standards, page 61 for fiber optic specifications.
Route the control wires from the Power Supply to the Pipe Interface Board. Then attach
the supplied six (6) pin control data connector to the wires in the Power Supply Box.
Installation Manual
Installing Roof Parapet and Pipe Mounts | en
F.01U.217.818 | 1.0 | 2011.04