OTHER ADJUSTMENTS
10.2 RADF Distortion Adjustment
Adjust the amount of distortion of a copy in the fol-
lowing procedures.
A. Procedure
1. Set a A3 paper on the tray of the main body.
2. Set the ADF adjustment chart on the RADF,
then make a copy.
3. Check the amount of distortion in the copy.
Standard value: ± 0.3% less.
[1]
A
[1]
Paper feed direction
4. When the distortion is larger than the tolerance,
adjust it using the skew adjustment screw [1].
• A: Turn the dskew adjustment screw [1] clock-
wise.
• B: Turn the skew adjustment screw [1] counter-
clockwise.
5. Repeat above steps 2 to 4 until the standard
value for distortion is met.
B
1-90
[1]