47 MODE

9. 47 MODE
9.1

47 Mode Setting Method

A. 47 Mode
This mode provides self-diagnostic functions (input/
output check function) to check and adjustment the
various signals and loads.
B. Operation method (to start 47 mode)
(1) 47 Mode startup
a.
Turn the SW2 (Sub power switch) OFF.
b.
Turn the SW2 ON while pressing 4 and 7 of the
copy quantity setting buttons.
If security enhancement is enabled, input CE
password.
c.
The moment "I/O check mode" is displayed in
the message display area at the center of the
screen, check to see if the 47 mode is acti-
vated.
"47 mode menu screen"
[1] [2]
[1]
Input/Output check code
[2]
Multi code
[3]
Input check
[4]
Output check
(2) Input check method
a.
Using the numeric keys, enter the code input
for the desired signal (sensor, etc.) to check.
b.
When using the multi mode, press the
and enter the multi code according to the
desired input check item (signal) with the
numeric keys.
2
[3]
[4]
button
1-76
c.
Procedure
1. Enter the 47 mode.
2. "47 mode menu screen"
Using the numeric keys, enter the input check
*
code.
1
3. When using the multi mode, press the
4. Using the numeric keys, enter the multi code.
5. Input check result will appear in the input check
result display area.
6. To check other signal input check, repeat steps
2 to 5.
*
1
See "[5] Input check list".
(3) Output check method
a.
Enter the output code (see the input/output
check code) of the operating load you want to
check with the number of sheets setting button.
b.
When using the multi mode, press the
and enter the multi code according to the
desired output check item (load).
c.
Press the [START] key to perform the output
check.
d.
To end the output check, press the [STOP] key.
e.
Procedure
1. Enter the 47 mode.
2. "47 mode menu screen"
Using the numeric keys, enter the output check
*
code.
2
3. When using the multi mode, press the
4. Using the numeric keys, enter the multi code.
5. Press the [START] key to perform the output
check.
6. To end the output check, press the [STOP] key.
7. To make another output check, repeat steps 2 to
6.
*
2
See "[6] Output check list".
(4) Exiting the 47 mode
To end the 47 mode, turn the SW2 OFF.
button.
*
1
button
button.
*