OTHER ADJUSTMENTS
10.18 Staple Angle Adjustment of
SK-114
• It is performed when the staple unit 1 or 2 is
replaced or a tilt occurs in center staple position.
A. Procedure
1. Set five A4 originals in the ADF.
2. Set to 2-point Staple and Crease mode and
make a copy. Check whether the staple position
is aligned correctly.
Specification: 0 ± 1.5mm
3. If the staple position is slanted as shown on the
figure, make the following adjustment.
4. Release the lock release lever of the Saddle
Unit.
5. Loosen one adjustment screw and move the
lock lever to the left to make the adjustment.
*
If the staple position is slanted opposite to the
figure of step 3, move the lock lever to the
right to make the adjustment.
6. Make another copy and check the staple posi-
tion.
1
A
Exit direction
1-112
4511D531AA
4511D532AA