7.11 Class 0x80 (Extended Object IV)

7.11.1 Class 0x80 Instance 1

Inverter monitored value can be read. Refer to the Instruction Manual of the inverter for details of each
monitor.
(1) Attribute
Attribute
Access
Description (Increments)
ID
11
Get
Output frequency
12
Get
Output current
13
Get
Output voltage
15
Get
Frequency setting
17
Get
Motor torque
18
Get
Converter output voltage
19
Get
Regenerative brake duty
Electronic thermal relay function
20
Get
load factor
21
Get
Output current peak value
Converter output voltage peak
22
Get
value
24
Get
Output power
*1
Input terminal monitor details (when the terminal is ON: 1, when the terminal is OFF: 0,
b15
*2
Output terminal monitor details (when the terminal is ON: 1, when the terminal is OFF: 0,
b15
(0.01Hz)
(0.01A)
(0.1V)
(0.01Hz)
(0.1%)
(0.1V)
(0.1%)
(0.1%)
(0.01A)
(0.1V)
(0.01kW)
RES
Attribute
Access
ID
25
Get
26
Get
30
Get
33
Get
34
Get
35
Get
62
Get
63
Get
64
Get
71
Get
72
Get
73
Get
MRS
RH
RM
ABC
OBJECT MAP
Description (Increments)
Input terminal status
*1
Output terminal status
*2
Cumulative energization time
Actual operation time
(1h)
Motor load factor
(0.1%)
Cumulative power
(1kWh)
PID set point
(0.1%)
PID measured value
(0.1%)
PID deviation
(0.1%)
Motor thermal load factor
(0.1%)
Inverter thermal load factor
Cumulative power 2
(0.01kWh)