Class 0X29 (Control Supervisor Object); Class 0X29 Instance 1 - Mitsubishi Electric FR-A7ND E kit Instruction Manual

Plug-in option
Hide thumbs Also See for FR-A7ND E kit:
Table of Contents

Advertisement

OBJECT MAP
7.6

Class 0x29 (Control Supervisor Object)

7.6.1

Class 0x29 Instance 1

(1) Attribute
Class 0x29 Instance 1
Attribute ID Access
3
Get/Set RUN1
4
Get/Set RUN2
5
Get/Set
6
Get
7
Get
8
Get
68
Name
NetCtrl
(operation command
source)
(Pr. 338)
State
Running 1
(forward rotation
command)
Running 2
(reverse rotation
command)
Initial
Range
Value
0
Stop
00
1
Forward rotation
0
Stop
00
1
Reverse rotation
Other than DeviceNet
0
communication operation
1
DeviceNet communication
1
operation
1
Startup
2
Not_Ready (during reset)
3
Ready (during stop)
Enabled (during acceleration, during constant
3
4
speed, during reverse deceleration)
5
Stopping (during deceleration)
6
Fault_Stop (during deceleration with Pr. 502)
7
Faulted (during alarm occurrence)
0
During stop
0
1
During forward rotation
0
During stop
0
1
During reverse rotation
Description
Actual state of
operation command
can be monitored
with Attribute 15.

Advertisement

Table of Contents
loading

Table of Contents