Class 0x05 Instance 2
Attribute ID
Access
9
Get/Set
12
Get/Set
13
Get
14
Get
15
Get
16
Get
*1
Since 2byte data is sent and received for Polling I/O message communication, the lowest byte is 0x00.
Produced Connection Path and Consumed Connection Path specifies Application Object of sent and received data. The
format is below.
0x62
0xMM
Logic address Application Object data
This is ASCII Code which shows input/output instance value (hexadecimal).
Name
Expected Packet Rate
(EPR)
Watchdog Action
Produced Connection
Path Length
Produced Connection
Path
Consumed Connection
Path Length
Consumed Connection
Path
0xNN
Range
0 to 0xFFFF
(Example) 2500: 2500ms
0
Transition to time out (initial value)
1
Auto Delete
2
Auto reset
Specifies the number of bytes of information within the
0 to 0xFFFF
produced_connection_path attriburte
The value specifies Application Object of sent data.
0x62, 0x34, 0x36: Assmbly Instance 70
00 to 0xFF
0x62, 0x34, 0x37: Assmbly Instance 71
0x62, 0x42, 0x30: Assembly Instance 176
Specifies the number of bytes of information within the
0 to 0xFFFF
consumed_connection_path attriburte
3: 3 byte
The value specifies Application Object of received data.
0x62, 0x31, 0x34: Assmbly Instance 20
00 to 0xFF
0x62, 0x31, 0x35: Assmbly Instance 21
0x62, 0x37, 0x45: Assmbly Instance 126