Lakeshore 332 User Manual page 50

Temperature controller
Table of Contents

Advertisement

Keypad Definitions (Continued)
Control Setup
Setpoint
Zone Settings
PID/MHP
Input Setup
Curve Entry
Display Format Allows the user to configure the display and select the units or other source of the
Math
Alarm
Analog Output
Remote/Local
Interface
s
t
Escape
Enter
0 – 9, +/–, .
4-2
Lake Shore Model 332 Temperature Controller User's Manual
Allows selection of control input, setpoint units, closed or open-loop control mode,
power up enable, display of heater output units, setpoint ramp enable, and ramp
rate for the currently selected loop. Refer to Paragraph 4.7 for control setup and
Paragraph 4.12 for ramp feature.
Allows entry of control setpoint for the currently selected loop. Refer to Paragraph
4.11. A discussion of the ramp feature is provided in Paragraph 4.12.
Allows entry of up to 10 temperature control zones of customer-entered PID
settings and Heater Ranges for the currently selected loop. Refer to Paragraph
4.10.
Allows manual adjustment of control parameters Proportional, Integral, and
Derivative, or Manual Heater Power (MHP) output for the currently selected loop.
Refer to Paragraph 4.8.
Allows selection of sensor input type and curve. Refer to Paragraph 4.4 for sensor
input setup and Paragraph 4.5 for curve selection.
Allows entry of up to twenty 200-point CalCurves or user curves and SoftCal.
Refer to Chapter 5 – Advanced Operation, Paragraph 5.2 Front Panel Curve
Entry Operations.
readings. Refer to Paragraphs 4.1.4, 4.1.5, and 4.3. Press and hold to set display
brightness. Refer to Paragraph 4.18.
Allows the user to configure the math features: Max/Min, linear equation, and filter.
Press twice to reset the stored Max/Min readings. Refer to Paragraph 4.14.
Allows the user to configure both the alarms and relays. Refer to Paragraph 4.15.
Allows the user to configure the analog output feature. Also used to assign the
analog output to Loop 2 control output thus enabling Loop 2. Refer to
Paragraph 4.16.
Sets remote or local operation: Remote refers to operation is via IEEE-488
Interface; Local refers to operation via the front panel. Refer to Paragraph 4.19.
Sets the Baud rate of the serial interface and IEEE-488 address and terminators.
Refer to Paragraph 4.20.
Serves two functions: chooses between parameters during setting operations and
to increment a numerical parameter values.
Serves two functions: chooses between parameters during setting operations and
decrements numerical parameter values.
Terminates a setting function without changing the existing parameter value. Press
and hold to reset instrument to default values. Refer to Paragraph 4.21.
Completes setting functions and returns to normal operation. Press and hold to
lock or unlock keypad. Refer to Paragraph 4.17.
Used for entry of numeric data. Includes a key to toggle plus (+) or minus (–), and a
key for entry of a decimal point. Refer to Paragraph 4.1.3.