Table 1-2. Model 332 Typical Sensor Performance Chart (Continued)
Sensor Type
Temperature Coefficient
Input Range
Sensor Excitation
*
(Constant Current)
Display Resolution
(Sensor Units)
Example Lake Shore Sensor
Standard Sensor Curve
Typical Sensor Sensitivity
Measurement Resolution:
Sensor Units
Temperature Equivalence
Electronic Accuracy:
Sensor Units
Temperature Equivalents
Temperature Accuracy including
electronic accuracy, CalCurve
and calibrated sensor
Control Stability:
Sensor Units
Temperature Equivalence
Magnetic Field Use
Current reversal eliminates thermal EMF voltage errors for resistor sensors.
*
Typical sensor sensitivities were taken from representative calibrations for the sensor listed.
NOTES:
NTC RTD Range 75 Ω
1
NTC RTD Range 750 Ω
2
3
NTC RTD Range 7500 Ω
NTC RTD Range 75000 Ω
4
1-6
Lake Shore Model 332 Temperature Controller User's Manual
Germanium
Germanium
GR-200A-1500
GR-200A-250
Negative
Negative
AutoRange
AutoRange
75 mV max
75 mV max
4 ranges from 75 Ω -
4 ranges from 75 Ω -
75 kΩ
75 kΩ
5 digits
5 digits
GR-200A-1500
GR-200A-250 with
with1.4D calibration
0.3D calibration
Requires calibrated
Requires calibrated
sensor
sensor
–64200 Ω/K at 1.4 K
–8450 Ω/K at 1 K
–668 Ω/K at 4.2 K
–68.9 Ω/K at 4.2 K
–0.078Ω/K at 77 K
–0.054 Ω/K at 77 K
Auto Range
Auto Range
see Table 1-3
see Table 1-3
<10 µK at 1.4 K
<10 µK at 1 K
4
30 µK at 4.2 K
40 µK at 4.2 K
3
3.8 mK at 77 K
5.5 mK at 77 K
1
Auto Range
Auto Range
see Table 1-3
see Table 1-3
±0.2 mK at 1.4 K
±0.2 mK at 1 K
4
±1 mK at 4.2 K
±2 mK at 4.2 K
3
±38 mK at 77 K
±47 mK at 77 K
1
±6 mK at 1.4 K
±6 mK at 1 K
4
±6 mK at 4.2 K
±7 mK at 4.2 K
3
±128 mK at 77 K
±137 mK at 77 K
1
±80 mΩ
±80 mΩ
±20 µK at 1.4 K
±20 µK at 1 K
4
±60 µK at 4.2 K
±80 µK at 4.2 K
3
±7.6 mK at 77 K
±11 mK at 77 K
1
Not Recommended
Not Recommended
Cernox™
CX-1070
Negative
AutoRange
75 mV max
4 ranges from 75 Ω -
75 kΩ
5 digits
CX-1070-SD with
1.4L calibration
Requires calibrated
sensor
–17600 Ω/K at 4.2 K
–-969 Ω/K at 10 K
–8.26 Ω/K at 77 K
–0.419 Ω/K at 300 K
Auto Range
see Table 1-3
<10 µK at 4.2 K
3
4
<100 µK at 10 K
2
3
3.6 mK at 77 K
1
2
7.2 mK at 300 K
2
Auto Range
see Table 1-3
±1 mK at 4.2 K
3
4
±3 mK at 10 K
2
3
±28 mK at 77 K
1
2
±128 mK at 300 K
2
±7 mK at 4.2 K
3
4
±11 mK at 10 K
2
3
±78 mK at 77 K
1
2
±268 mK at 300 K
2
±80 mΩ
±20 mK at 4.2 K
3
4
±7.2 mK at 77 K
2
2
±14.4 mK at 300 K
1
2
Recommended for
T > 2 K & B ≤ 19 T
Cernox™
Cernox™
CX-1050
CX-1030
Negative
Negative
AutoRange
AutoRange
75 mV max
75 mV max
4 ranges from 75 Ω -
4 ranges from 75 Ω -
75 kΩ
75 kΩ
5 digits
5 digits
CX-1050-SD with
CX-1030-SD with
1.4L calibration
1.4L calibration
Requires calibrated
Requires calibrated
sensor
sensor
–-42800 Ω/K at 2 K
–-8670 Ω/K at 1.4 K
–2290 Ω/K at 4.2 K
–138 Ω/K at 4.2 K
–2.15 Ω/K at 77 K
–-.828 Ω/K at 77 K
–0.131 Ω/K at 300 K
–0.067 Ω/K at 300 K
Auto Range
Auto Range
see Table 1-3
see Table 1-3
<10 µK at 2 K
<10 µK at 1.4 K
4
<10 µK at 4.2 K
20 µK at 4.2 K
3
1.2 mK at 77 K
3.6 mK at 77 K
2
2.3 mK at 300 K
4.5 mK at 300 K
1
Auto Range
Auto Range
see Table 1-3
see Table 1-3
±0.3 mK at 2 K
±0.2 mK at 1 K
4
±1 mK at 4.2 K
±2 mK at 4.2 K
3
±30 mK at 77 K
±57 mK at 77 K
2
±130 mK at 300 K
±224 mK at 300 K
1
±6 mK at 2 K
±6 mK at 1.4 K
4
±7 mK at 4.2 K
±8 mK at 4.2 K
3
±80 mK at 77 K
±107 mK at 77 K
2
±270 mK at 300 K
±364 mK at 300 K
1
±80 mΩ
±80 mΩ
±8 µK at 2 K
±20 µK at 1.4 K
4
±20 µK at 4.2 K
±40 µK at 4.2 K
3
±2.4 mK at 77 K
±7.2 mK at 77 K
2
±4.58 mK at 300 K
1
±9 mK at 300 K
Recommended for
Recommended for
T > 2 K & B ≤ 19 T
T > 2 K & B ≤ 19 T
Introduction
3
2
2
1
3
2
2
1
3
2
2
1
3
3
3
3