Config Mld_Snooping Querier; To Configure The Mld Snooping Querier - D-Link xStack DGS-3400 Cli Manual

Xstack dgs-3400 series layer 2+ gigabit ethernet managed switch
Hide thumbs Also See for xStack DGS-3400:
Table of Contents

Advertisement

xStack
D G S –3 4 26 :5 # c on f ig m l d _s n oo pi n g m r ou te r _ po r ts _f o r bi d de n d e fa u lt a d d 1 : 11 –1 : 2 0
C o m ma n d : c o nf i g ml d _ sn o op in g mr o ut er _ p or t s_ fo r b id d en d e f au l t ad d 1: 1 1– 1: 2 0
S u c ce s s
D G S –3 4 26 :5 #

config mld_snooping querier

Purpose
Syntax
Description
Parameters
Restrictions
Example usage:

To configure the MLD snooping querier:

D G S –3 4 26 :5 # c on f ig m l d _s n oo pi n g q u er ie r vl a n de f a ul t q ue r y _i n te rv a l 1 2 5 st a t e
e n a bl e
C o m ma n d : c o nf i g ml d _ sn o op in g qu e ri er v la n d ef a u lt qu er y _ in t er va l 12 5 s ta t e
e n a bl e
S u c ce s s.
D G S –3 4 26 :5 #
®
DGS-3400 Series Layer 2 Gigabit Managed Switch CLI Manual
Used to configure the timers and settings for the MLD snooping querier for the Switch.
config mld_snooping querier [ vlan <vlan_name 32> |all] { query_interval <sec 1-
65535> | max_response_time <sec 1-25> | robustness_variable <value 1-255> |
last_listener_query_interval <sec 1-25> | state [enable|disable] | version <value 1-
2>} (1)
This command is used to configure the time between general query transmissions, the
maximum time to wait for reports from listeners and the permitted packet loss guaranteed
by MLD snooping.
vlan <vlan_name 32> − The name of the VLAN for which to configure the MLD querier.
all – Specifies all VLANs are to be configured for the MLD querier.
query_interval <sec 1–65535> – Specifies the amount of time between general query
transmissions. The user may specify a time between 1 and 65535 seconds with a default
setting of 125 seconds.
max_response_time <sec 1–25> – The maximum time to wait for reports from listeners.
The user may specify a time between 1 and 25 seconds with a default setting of 10
seconds.
robustness_variable <value 1–255> – Provides fine–tuning to allow for expected packet
loss on a subnet. The user may choose a value between 1 and 255 with a default setting
of 2. If a subnet is expected to be lossy, the user may wish to increase this interval.
last_listener_query_interval <sec 1–25> – The maximum amount of time to be set
between group–specific query messages. This interval may be reduced to lower the
amount of time it takes a router to detect the loss of a last listener group. The user may
set this interval between 1 and 25 seconds with a default setting of 1 second.
state [enable | disable] – Enabling the querier state will set the Switch as a MLD querier
and disabling it will set it as a Non–querier. The default setting is disabled.
version <value 1-2> – Configure the MLD version of the query packet which will be sent
by the router. The default is 2.
Only Administrator and Operator-level users can issue this command.
178

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xstack dgs–3426

Table of Contents