1 TROUBLESHOOTING FOR THE HARDWARE
 Staple jam in the saddle stitch unit
1
Open the lower front cover of the finisher.
2
Slowly pull out the saddle stitch unit.
3
Pull the stapler handle on the saddle stitch unit
toward you to unlock it. Then turn the stapler
clockwise by 60 degrees.
The stapler is locked and cannot be turned further when it lies
almost horizontally.
4
Remove the staple cartridge.
Pull up the staple cartridge while pushing both sides.
5
While pushing the green lever downward, pull up the
shutter with the knob.
Do not touch the stapling area.
The actual needle point could cause you personal injury.