Sharp R-9320 Service Manual page 56

Microwave oven
Table of Contents

Advertisement

R-9320
TURNTABLE
MOTOR
REMOVAL
1. Disconnect the oven from the power
supply.
2.
Remove
the six (6) screws holding the base cabinet (8)
to the oven cavity and rear cabinet.
3. Shift the base cabinet (B) to the left to release the tab of
the base cabinet (B) from the base cabinet
(A).
4. Remove the base cabinet (B).
6. Remove
the
four
(4) screws holding
the turntable
motor
mounting plate
to the oven cavity bottom.
6. Disconnect
the
wire
leads
from
the
turntable
motor.
7. Remove
the four
(4) screws holding
the turntable
motor
to the mounting
plate.
The motor
is now free.
TURNTABLE
ROLLER
REMOVAL
1. Disconnect
the oven from
the power supply and remove
the outer case.
Turntable
roller
Oven
cavtty
2. Discharge the high voltage
capacitor.
3.
Remove the
six (6) screws holding
the
base cabinet (B)
to the oven cavity and rear
cabinet.
4. Remove the turntable
roller cover.
5. Pull off
the
turntable roller shaft.
Re-installing
'
Roller
cover
1.
2.
3.
Set the turntable roller in place.
Insert the turntable roller shaft
into the turntable
roller
through the hole.
Carefully attached
the
roller
cover,
refer
to
Figure 20.
FAN
MOTOR
REMOVAL
1.
2.
3.
4.
5.
Disconnect the
oven from
the power supply and remove
6. Remove
the duct
(A) with
the fan motor
attached
from
the outer case.
the unit.
Discharge the high voltage capacitor.
7. Remove
the fan blade from
the fan motor
shaft
by
pull-
Disconnect the wire leads from the fan motor.
ing the fan retainer
clip.
Remove the three (3) screws holding the chassis
support
8. Remove
the
two
(2)
screws and nuts holding
the fan
to the rear cabinet, cooling duct (A) and control
panel
motor to the cooling duct (A).
back plate.
.
The fan motor
is now free.
Release the tab which is provided on the cooling
duct
(B)
to hold the cooling duct (A).
MAGNETRON
REMOVAL
1.
2.
3.
4.
5.
6.
7
Disconnect
the oven from
the
power
suppluy
and
the magnetron to the waveguide while supporting
the
remove the outer case.
magnetron from below.
Discharge
the high voltage capacitor.
8. Lower the magnetron assembly until the tube is clear of
Disconnect the wire leads from the magnetron and the
the waveguide.
magnetron temp. fuse.
9. Remove the magnetron temp. fuse and magnetron duct
Release
the tab which is provided on the cooling duct
by loosening the mounting screws.
(B) to
hold the cooling duct (A).
CAUTION.
WHEN
REPLACING
THE
MAGNETRON,
Remove the
two
(2)
screws
holding
the cooling
duct
BE
SURE THE R.F. GASKET IS IN PLACE
(B) to the magnetron.
AND
MOUNTING
NUTS
ARE
TIGHTEN-
Remove the cooling duct
(B) from the unit.
ED SECURELY.
. .
Carefully loosen the four (4) mounting screws holding
Roller
support
Figure
20. Turntable
Roller
Re-installing
54