WARNING:
to avoid possible exposure
to
microwave
energy;
A. Before operating the oven;
1. Make sure that
unlatching the door slowly is ac-
companied by a click indicating actuation of the latch
switches.
2. There is a broken door hinge or support.
3. The door gasket or seal is damaged.
4. The door is bent or warped.
5. There is any defective parts in the interlock, oven
door
or
microwave
generating
and
transmission
assembly.
2. Check visually the door seal for arcing and/or damage.
6. There is any other visible damage
to the oven.
8. Do not operate the oven until after repair if any of the
C.
Do
not operate the oven;
following conditions exist;
1. Without the RF gasket.
1. Door
does not close firmly
against the front of
2. If the waveguide and oven cavity are not
intact.
appliance.
3. If the door is not closed.
OUTER CASE REMOVAL
To remove
the
outer case,
refer to
Figure 19
and proceed as
3.
Slide the entire case back about 3cm to
free
it from
follows:
retaining clips on the
cavity
face plate.
1.
Disconnect the oven from
the
power supply.
4.
Lift the entire case from the unit.
2.
Remove the screws from the rear and along
the side
CAUTION:
DISCHARGE
THE HIGH VOLTAGE
CAPA-
edge of the case.
CITOR
BEFORE
TOUCHING
ANY
OVEN
COMPONENTS
OR WIRING.
HIGH VOLTAGE
COMPONENTS
REMOVAL
(High Voltage Capacitor and Rectifier)
To remove the components, proceed as follows.
4. Remove the single (1) screw holding
the
capacitor holder
1. Disconnect the oven from the power supply and remove
to the mounting
bracket,
and remove the capacitor
the outer case.
holder.
2. Discharge the high voltage capacitor.
5. Now, the capacitor and rectifier are free.
3. Disconnect the wire leads from the high voltage
capaci-
CAUTION:
WHEN
REPLACING
THE
RECTIFIER,
tor.
THE
EARTH
SIDE
TERMINAL
MUST
BE SECURED
FIRMLY
WITH
A EARTH-
ING SCREW.
POWER TRANSFORMER
REMOVAL
1. Disconnect the oven from the power supply and remove
the outer case.
2. Discharge the high voltage capacitor.
3. Disconnect the wire leads from the power transformer.
4. Disconnect the filament leads from the magnetron and
high voltage capacitor.
5. Remove the two (2) screws holding the transformer to
the base cabinet (A).
6. Remove the transformer.
COOK RELAY
AND CONTROL
RELAY
REMOVAL
1. Disconnect the oven from the power supply and remove
the outer case.
2. Discharge the high voltage capacitor.
3. Disconnect the wire leads from the cook relay and
control relay.
4. Remove the single (1) screw holding the relay angle
to the base cabinet (A).
5. Slide the relay angle backward and remove it.
6. Now, the cook relay and control relay are free.
OVEN LAMP REMOVAL
1. Disconnect the oven from the power supply.
2. Loosen the screw to
open
then remove the oven lamp.
the lamp access cover, and