Sharp R-9320 Service Manual page 51

Microwave oven
Table of Contents

Advertisement

R-9320
R-9450
TEMPERATURE
MEASUREMENT
CIRCUIT
(On R-9450
Alone)
Fig. 15 shows the temperature
measurement
circuit.
The
thermistor
in the temperature
probe varies in resistance ac-
cording
to the cooking
temperature
and this variation
is con-
verted to analog voltage variation
to be delivered
to the
K4
terminal
of LSI which contains an A/D converter.
In the LSI
there are produced
"H"
level signal and "L"
level signal at
its
output terminal
D7, as shown in Fig. 16.
When the output
signal of
the
terminal
D7
is at "H" level, the
transistor
Q5 turns on
to get
R62 shorted,
and the circuit
equivalent
to that shown in Fig. 17-(a)
is set
up.
With
this
equivalent
circuit
in operation,
the LSI can
perform
the tem-
perature measurement
through the temperature
probe.
When the output
signal of the terminal
D7 is at "L"
level, the
transistor
Q5 turns off to get R62 and R61 connected
in series
with
each other,
and the circuit
equivalent
to that shown in
Fig. 17-(b) is set up. With this equivalent
circuit in operation,
.
the LSI judges whether
the temperature
probe is opened or
not:
that
is, when
the temperature
probe
is opened,
the
voltage almost
equal to VREF/~ is applied
to the
K4 terminal
of LSI; when it is not opened (at its normal state), the voltage
lower than VREF/~
is applied
thereto.
With the temperature
probe
opened,
the temperature
indicator
and numeral
indi-
cator flash to indicate
this
state.
TEMP.
PROBE
LSI
Figure 15. Temperature
Measurement
Circuit
"H"
t
GND
i
Judge)
(Temp.
Measurement)
I
I
I
I
Figure 16. Signal Output Timing at 08 Terminal
;yk-
K4 (To LSI,
v;Tb--
K4 (To Lsl)
(a) D7
terminal
"H"
lb)
D7
terminal
"I-'*
Figure
17. Circuit
Equivalent to Temperature
Measurement
Circuit
49