In No.
Signal
36
P2
l/O
OUT
Description
.Key strobe
signal.
Signal applied to touch-key
section.
/
j DEFROST
/
A
pulse signal is generated while 2,
m,
m
or ;
:
1
i
key is being touched.
37
P3
OUT
Key strobe signal.
Signal applied to touch-key
section.
A
pulse signal is generated
while 3, ISToP
IMED]
or [
/
key is being touched.
38
NC
39
VREF
NC
IN
Terminal
not used.
Reference
voltage input terminal
A reference
voltage applred to the A/D converter
In the
LSI
The reference
voltage IS generally
maintained
at -6.2V.
40
KO
IN
I
Signal coming from touch-key.
When either
one of 6, 5, 4, 3, 2, 1, or 0 key is touched,
a corresponding
signal out
of QO - Q2 and PO - P3 will be input into KO.
When no key is touched,
the signal is held at "L" level i-l
2Vi.
41
Kl
IN
Signal similar to KO.
I
j TEMP
When either one of 9, 8, 7, STOP,
(CLEAR;,
i ("C)
or 'START
key is touched,
a crresponding
signal will
be
input into KI.
; : R-9450
only).
42
K2
IN
Signal similar to KO.
When either
one of m,
j,
I
1
b=-j
,
j M. HIGH;,
key is touched,
a crresponding
signal will be input
in to K2.
43
K3
IN
Signal similar to KO
When either one of
,
F]
,
E!
or
m]
key is touched,
a crresponding
signal will be input
into K3.
: R-9450 only)
K4
IN
Temperature
measurement
input
By inputting
DC voltage corresponding
to the temperature
detected
by the tem-
perature
probe,
this input is converted
into temperature
by the A/D
converter
in
which
LSI is built in.
45
K5
46
K6
IN
IN
Terminal
to change the functions
according
to the Models.
By using the A/D
converter
contained
in the
LSI
(IX2321YA),
DC
voltage
In
accordance
with the Model in operation
is applied to set up Its function.