Sharp R-9320 Service Manual page 37

Microwave oven
Table of Contents

Advertisement

TEST
PROCEDURES
KONT'D)
R-9320
R-9450
~~~
/ PROCEDURE
:
LETTER
COMPONENT
TEST
,
1
I
M
TEMPERATURE
PROBE
TEST
(R-9450
ONLY)
I
1 Disconnect
the temperature
probe
from
the unit, and check for the continuity
of the probe, connecting
an
:
/
ohmmeter
to its plug.
/
I
I
On the R x 1 kilo-ohm
scale, the resistance of the probe should be approx.
42.6 to 58.0
kilo-ohms
at room
'
temperature
25'C,
and approx.
3.7 to 4.1 kilo-ohms
at 93°C
.
,
To check the resistance at 93'C,
proceed as follows:
/
'
1. Fill 9 ounces (275
milliliters)
of tap water
in a 2 cup measuring
cup, and place the temperature
probe
into the water.
2. Place the container
and probe in the center of the oven cavity.
3. Connect the probe to the receptacle
which
is provided
at the top of oven cavity.
4. Close the door.
5. Set the cooking
temperature
to 93°C
and touch the cook pad.
6. Approximately
4 minutes
later,
the cook
cycle
will
be completed.
At
this-time,
the temperature
of
water should be approximately
93°C.
7. Disconnect
the probe from the receptacle
and check for the resistance of probe immediately.
If the resistance differs from the above, the probe should be replaced.
N
TOUCH
CONTROL
PANEL
ASSEMBLY
TEST
The touch
controi
panel consists of circuits
including
semiconductors
such as LSI,
ICs, etc. Therefore,
unlike
the conventional
microwave
ovens, proper
maintenance
cannot
be performed
with only a voltmeter
and ohmmeter.
Refer to the "TOUCH
CONTROL
PANEL
ASSEMBLY".
35